DIN 103

Last Updated: November 6, 2026

Lead Screw and Acme Power Screw Torque and Efficiency

A DIN 103 Tr40×7 single-start trapezoidal lead screw lifting a 25 kN axial load (μt=0.15, μc=0.02) requires 115.3 N·m raising torque at 24.2% mechanical efficiency and is self-locking.

Interactive DIN 103 Trapezoidal & ASME B1.5 Acme Power Screw Torque Solver

Custom μ_t:
Custom μ_c:
Mode 1: Forward Analysis

Lifting Torque, Self-Locking & Structural Check

Self-Locking (Safe)
Total Raising Torque (T_raise)
115.3 N·m
Thread: 99.6 N·m + Collar: 15.6 N·m
Mechanical Efficiency (η_total)
24.2%
Screw thread only: 28.0%
Lowering Torque (T_lower)
58.2 N·m
Positive torque required to lower load
Bronze Nut Bearing PressureMax Safe: 18 MPa
7.3 MPa
P = 2F / (π · dm · H_nut). Within bronze nut fatigue endurance limits.
Euler Critical Buckling Load (F_crit)SF Limit: ≥ 2.5
473.4 kN (SF = 18.94)
Governed by shaft root core Ø dr = 33.0 mm.
Thread Wedge & Mechanics of Power Screws (Shigley §8-2)● Self-Locking (λ < φ)
DIN 103 Metric Trapezoidal (30°)Major Ø d = 40.0 mmPitch Ø dm = 36.5 mmRoot Ø dr = 33.0 mmα = 15°Unwrapped Pitch Cylinder Wedge (tan λ = L / π·dm)λ = 3.49°Load FCircumference: π · dm = 114.7 mmLead L = 7.0 mmT_raise = 115.3 N·m✓ SELF-LOCKING SAFE: λ (3.49°) < φ (8.5°)
HEAVY EQUIPMENT ACTUATOR & SHOP SPECIFICATIONS

Avoid Costly Restocking Fees & Lead Screw Stripping Downtime

Salah memesan komponen pengganti atau salah menghitung spesifikasi ulir memicu denda restocking fee 20%–25% yang membuat bengkel kehilangan 26,59% hingga 31,18% dari total pengeluaran kas awal termasuk ongkos kirim balik (TallyCrunch Restocking Fee Benchmark Analysis 2026). Pastikan spesifikasi ulir DIN 103 / Acme Anda presisi sebelum memesan part.

DIN 103

Standard Trapezoidal & Acme Thread Dimension Matrix

Standard ISO metric trapezoidal screw threads (Tr 16×4 to Tr 80×10) and ASME B1.5 general-purpose Acme threads (3/4"-6 to 2-1/2"-3). Includes nominal pitch diameter $d_m$, root core diameter $d_r$, lead angle $\lambda$, and baseline raising torque per 10 kN thrust load.

Filter by Thread Standard Profile:

Tr 16 × 4

DIN 103 Profile

DIN 103Self-Locking ✅
Major Ø:16.00 mm
Pitch p:4.00 mm
Lead Angle:5.19°
Torque/10kN:17.6 N·m

Acme 3/4" - 6

ASME B1.5 Profile

ASME B1.5Self-Locking ✅
Major Ø:19.05 mm
Pitch p:4.23 mm
Lead Angle:4.54°
Torque/10kN:21.1 N·m

Tr 20 × 4

DIN 103 Profile

DIN 103Self-Locking ✅
Major Ø:20.00 mm
Pitch p:4.00 mm
Lead Angle:4.05°
Torque/10kN:21.8 N·m

Tr 24 × 5

DIN 103 Profile

DIN 103Self-Locking ✅
Major Ø:24.00 mm
Pitch p:5.00 mm
Lead Angle:4.24°
Torque/10kN:26.2 N·m

Acme 1" - 5

ASME B1.5 Profile

ASME B1.5Self-Locking ✅
Major Ø:25.40 mm
Pitch p:5.08 mm
Lead Angle:4.05°
Torque/10kN:27.6 N·m

Tr 30 × 6

DIN 103 Profile

DIN 103Self-Locking ✅
Major Ø:30.00 mm
Pitch p:6.00 mm
Lead Angle:4.05°
Torque/10kN:32.7 N·m

Acme 1-1/4" - 5

ASME B1.5 Profile

ASME B1.5Self-Locking ✅
Major Ø:31.75 mm
Pitch p:5.08 mm
Lead Angle:3.17°
Torque/10kN:33.8 N·m

Tr 36 × 6

DIN 103 Profile

DIN 103Self-Locking ✅
Major Ø:36.00 mm
Pitch p:6.00 mm
Lead Angle:3.31°
Torque/10kN:38.3 N·m

Acme 1-1/2" - 4

ASME B1.5 Profile

ASME B1.5Self-Locking ✅
Major Ø:38.10 mm
Pitch p:6.35 mm
Lead Angle:3.32°
Torque/10kN:39.6 N·m

Tr 40 × 7

DIN 103 Profile

DIN 103Self-Locking ✅
Major Ø:40.00 mm
Pitch p:7.00 mm
Lead Angle:3.50°
Torque/10kN:42.1 N·m

Acme 1-3/4" - 4

ASME B1.5 Profile

ASME B1.5Self-Locking ✅
Major Ø:44.45 mm
Pitch p:6.35 mm
Lead Angle:2.81°
Torque/10kN:45.4 N·m

Tr 50 × 8

DIN 103 Profile

DIN 103Self-Locking ✅
Major Ø:50.00 mm
Pitch p:8.00 mm
Lead Angle:3.17°
Torque/10kN:51.5 N·m

Acme 2" - 4

ASME B1.5 Profile

ASME B1.5Self-Locking ✅
Major Ø:50.80 mm
Pitch p:6.35 mm
Lead Angle:2.43°
Torque/10kN:49.8 N·m

Tr 60 × 9

DIN 103 Profile

DIN 103Self-Locking ✅
Major Ø:60.00 mm
Pitch p:9.00 mm
Lead Angle:2.96°
Torque/10kN:60.9 N·m

Acme 2-1/2" - 3

ASME B1.5 Profile

ASME B1.5Self-Locking ✅
Major Ø:63.50 mm
Pitch p:8.47 mm
Lead Angle:2.61°
Torque/10kN:63.9 N·m

Tr 70 × 10

DIN 103 Profile

DIN 103Self-Locking ✅
Major Ø:70.00 mm
Pitch p:10.00 mm
Lead Angle:2.80°
Torque/10kN:70.4 N·m

Tr 80 × 10

DIN 103 Profile

DIN 103Self-Locking ✅
Major Ø:80.00 mm
Pitch p:10.00 mm
Lead Angle:2.43°
Torque/10kN:79.2 N·m
SHIGLEY §8-2

Lead Screw Physics, Collar Friction & Bearing Pressure Limits

Understand the physical wedging forces driving power screws, how thrust collar friction consumes motor torque, when multi-start screws trigger hazardous back-driving, and why bronze nut bearing pressure must remain under 18 MPa.

Analytical Mechanics of Power Screws (DIN 103, ASME B1.5 & Shigley §8-2)

Power screws convert rotary drive torque into high-force linear motion in heavy machinery, trailer landing gear jacks, portable line boring feeds, and machine tool slides. Unlike standard fastening bolts governed by ISO 898-1 clamping preload (T = K·F·d), power screws operate under dynamic sliding contact governed by the inclined plane wedge equations developed in Shigley's Mechanical Engineering Design (§8-2) and standardized under DIN 103 (ISO 2901–2904) for metric trapezoidal threads and ASME B1.5 for imperial Acme threads.

EQUATION 1 & 2·TORQUE DERIVATION

Raising Torque (T_raise) & Lowering Torque (T_lower)

When driving a compressive axial load F, the total input torque is the sum of thread torque and parasitic thrust collar friction torque:

T_thread,raise = (F · dm / 2) · [ (L + π · μt · dm · sec α) / (π · dm - μt · L · sec α) ]
T_collar = (F · μc · dc) / 2
T_raise = T_thread,raise + T_collar

For lowering the load, thread friction acts in the opposite direction. If positive torque is required to turn the screw down, the screw is self-locking:

T_thread,lower = (F · dm / 2) · [ (π · μt · dm · sec α - L) / (π · dm + μt · L · sec α) ]
T_lower = T_thread,lower + T_collar
PHYSICS PRINCIPLE·OVERHAULING HAZARD

Self-Locking Condition vs. Back-Driving

A lead screw is self-locking if and only if the friction force on the unwrapped thread wedge exceeds the tangential driving component of the load:

Self-Locking Safe: tan(λ) < μt · sec(α)
Overhauling Hazard: tan(λ) ≥ μt · sec(α)

On single-start DIN 103 and Acme screws, lead angle λ is typically 2.5° to 4.5°, which is well below the friction angle φ = arctan(μt) ≈ 7° to 10°. However, multi-start screws (n = 2, 3, 4) have much higher lead (L = n · p), causing tan(λ) to exceed friction and allowing vertical loads to freefall!

EQUATION 3·BRONZE NUT CONTACT

Thread Bearing Pressure (P_bearing) & Stripping Limits

The axial thrust load is supported by the projected helical thread flanks of the mating nut. With nut engagement height H_nut and pitch diameter dm:

P_bearing = (2 · F) / (π · dm · H_nut) [MPa]

Machinery standards (Machinery's Handbook 31st Ed.) dictate that SAE 660 / CuSn12 bronze nuts must not exceed 18 MPa (2,600 psi) under intermittent low-speed operation. Continuous cycling applications require P_bearing ≤ 10–12 MPa to avoid destructive galling and accelerated backlash wear.

EQUATION 4·EULER COLUMN STABILITY

Euler Critical Column Buckling (F_crit)

Compressively loaded lead screws act as slender structural columns. Buckling resistance is dictated by the root core diameter dr (I_root = π · dr⁴ / 64):

F_crit = (C · π² · E · I_root) / L_col² [N]
Buckling Safety Factor: SF = F_crit / F ≥ 2.5

For trailer landing jacks and unguided traveling cantilever nuts (Fixed-Free), the end fixity factor drops to C = 0.25, reducing buckling capacity to only one-fourth of supported ends!

DIN 103 Metric Trapezoidal vs. ASME B1.5 Acme Geometry Comparison

FeatureDIN 103 / ISO 2901-2904 (Metric)ASME B1.5 (Acme Imperial)Square Thread
Included Thread Angle (2α)30°29°0°
Flank Half-Angle (α)15° (sec α = 1.0353)14.5° (sec α = 1.0329)0° (sec α = 1.0000)
Pitch SpecificationPitch p in mm (e.g. Tr40×7 → 7 mm)Threads per inch (TPI → p = 25.4 / TPI)Custom mm or in
Manufacturability & WearExcellent (die chasers, CNC turning)Excellent (standardized taps/dies)Difficult; cannot compensate for wear
Common ApplicationsEuropean machinery, ISO machine tools, jacksNorth American machine tools, trailer gearVises and legacy mechanical jacks

Verified Mechanical Engineering References & Standards

Frequently Asked Questions — Lead Screw & Acme Power Screws

Heavy equipment engineering and workshop answers on thread angles, self-locking conditions, thrust collar bearing friction, and bronze nut stripping limits.

What is the physical difference between DIN 103 metric trapezoidal thread and ASME B1.5 Acme thread?

The primary geometric distinction is the profile thread angle. DIN 103 (ISO 2901-2904) specifies a 30° included profile angle (15° flank half-angle) with metric pitches in millimeters (e.g., Tr40×7 has a 40 mm major diameter and 7 mm pitch). ASME B1.5 Acme threads specify a 29° included angle (14.5° flank half-angle) with pitches designated in threads per inch (TPI). Because the flank angles are virtually identical (15° vs 14.5°), their mechanical wedging and torque formulas follow the exact same Shigley §8-2 power screw mechanics, but tooling and thread gauges cannot be interchanged.

How do you determine if a lead screw is self-locking or will drop the load (back-drive)?

A lead screw is self-locking when the lowering torque is positive, meaning external torque must be applied to lower the load. Mathematically, this condition is satisfied when tan(λ) < μ_t · sec(α), where λ is the lead angle, μ_t is the thread friction coefficient, and α is the flank angle (15° for DIN 103, 14.5° for Acme). If tan(λ) > μ_t · sec(α), the thread is non-self-locking (overhauling) and the load will cause the screw to back-drive uncontrollably under gravity unless an automatic holding brake or self-locking worm gearbox is installed.

Why does collar friction torque (T_collar) account for such a high percentage of motor torque?

The entire axial thrust load F reacts against the stationary mounting frame through a thrust collar or shoulder bearing. Collar friction torque is calculated as T_c = (F · μ_c · d_c) / 2. With a plain steel or bronze thrust washer (μ_c = 0.08–0.15), collar friction often consumes 30% to 50% of the total input torque. Installing a rolling-element thrust ball or needle roller bearing (μ_c = 0.015–0.02) slashes collar torque by up to 80%, substantially reducing drive motor size and operating temperature.

What causes bronze nut thread stripping and how do you calculate bearing pressure?

Bronze nuts (SAE 660 / CuSn12) strip when the projected thread flank bearing pressure exceeds allowable material limits. The formula is P_bearing = (2 · F) / (π · d_m · H_nut). For continuous or frequent operation, bearing pressure must remain under 10–12 MPa (1,450–1,740 psi). For low-speed intermittent workshop jacks or slide positioning, 18 MPa (2,600 psi) is the absolute upper ceiling. Exceeding 18 MPa causes severe plastic galling, bronze shredding, and rapid backlash growth.

How does column buckling restrict long lead screw shaft capacity?

When a power screw pushes a compressive axial load over a long unsupported length (L_column), the slender shaft behaves as an Euler column. Buckling capacity is governed by the core root diameter d_r (where I_root = π · d_r⁴ / 64) and the end fixity factor C. In cantilever fixed-free jack screws, C = 0.25, which dramatically reduces critical force F_crit. To prevent catastrophic shaft bowing, Shigley and machinery standards mandate a safety factor SF ≥ 2.5 against Euler critical load.

What is the advantage and risk of using multi-start lead screws?

Multi-start threads have multiple interleaved thread helices (starts n = 2, 3, or 4). The lead L equals n × pitch p, producing rapid linear travel per shaft revolution (v = n_rpm · L / 60) without requiring an excessively coarse pitch. However, a larger lead dramatically increases the lead angle λ. While mechanical efficiency rises, the screw frequently loses its self-locking capability, turning into an overhauling drive that cannot safely support vertical loads without external braking.

Shop bench

Free shop calculators grounded in published standards (Parker Catalog 4300, SAE J1939, AS568). They run in the browser with no login and no paywall.

Need the Exact Factory Schematic or Torque Table for This Machine?

Stop scrolling through 1,200 to 4,000-page OEM PDFs on a phone screen. Upload your shop's Service and Test & Adjust manuals into Rigovely's isolated Scoped OEM Index. The Beta diagnostic co-pilot pinpoints the wiring pinout, relief pressure, or torque sequence by S/N prefix alongside Fleetio, SAP, or Maximo.

100% Shop-Controlled Library: Your internal manuals are encrypted and never used to train public AI models.Start 7-Day Free Trial - Upload Your Shop PDFs
View All Free Tools
Shop Downtime & ROI Scenario Calculator
01 · Fleet & Shop Economics

Shop Downtime & ROI Scenario Calculator

Model technician manual search friction, wrong-part restocking penalties, and independent equipment downtime using your shop’s actual repair order volume.

  • SMRP Metric 5.6.1
  • USACE EP 1110-1-8
  • Multi-Currency ROI
AS568 Hydraulic O-Ring Size & Nominal Gland Calculator
02 · SAE AS568 · Parker 2-xxx

AS568 Hydraulic O-Ring Size & Nominal Gland Calculator

Identify standard AS568 dash numbers and Parker 2-xxx designations from caliper ID and CS measurements with tolerance overlap and rectangular gland fill math.

  • SAE AS568 Rev D
  • Parker ORD 5700
  • 2D Interval Overlap
Hydraulic Fitting Torque & Thread Reference
03 · JIC 37° · ORFS · SAE ORB

Hydraulic Fitting Torque & Thread Reference

Look up thread designations, sealing mechanisms, and manufacturer assembly conditions for JIC 37° flare, ORFS face seal, and SAE O-ring boss connections.

  • SAE J514 · J1453
  • SAE J1926-1 ORB
  • No 0.75× Multipliers
Fastener Preload & Bolt Torque Calculator (T = K × F × d)
04 · ISO 898-1 · SAE J429

Fastener Preload & Bolt Torque Calculator (T = K × F × d)

Calculate tensile stress area (As), proof load, target clamp preload (F), and tightening torque (T = K × F × d) with explicit nut factor K and anti-seize yield risk simulation.

  • ISO 898-1 Class 8.8/10.9/12.9
  • SAE J429 Grade 5/8
  • Bossard F-047
SAE J1939 Fault Code (SPN/FMI) & Deutsch 9-Pin Reference
05 · SAE J1939-73 · Deutsch 9-Pin

SAE J1939 Fault Code (SPN/FMI) & Deutsch 9-Pin Reference

Decode 5-bit Failure Mode Identifiers (FMI 0–31), curated Suspect Parameter Numbers (SPN), proprietary OEM SPN ranges, and Deutsch HD10-9-1939 9-pin connector cavities.

  • SAE J1939-73 FMI 0–31
  • Deutsch HD10-9-1939
  • Gateway Guardrails
SAE J518 4-Bolt Split Flange (Code 61 / Code 62 / CAT) Calculator
06 · SAE J518 · Parker 4300 T6

SAE J518 4-Bolt Split Flange (Code 61 / Code 62 / CAT) Calculator

Match caliper flange head OD, thickness, and bolt pattern to SAE Code 61, Code 62, or Caterpillar 14.22 mm (0.560") high-pressure flanges with AS568 O-ring and 3-step cross-bolt torque specs.

  • SAE J518 / ISO 6162
  • Code 62 vs CAT 14.22 mm
  • Parker Table T6