Hydraulic Motor Speed, Torque, and Displacement per ISO 4391

An orbital motor (400 cc/rev) supplied with 40 L/min at 200 bar delivers 92 RPM and 1,120 N·m torque with 10.8 kW mechanical power — calculated per ISO 4391.

Interactive Hydraulic Motor Shaft Speed, Torque, and Sizing Calculator

Calculated hydraulic motor: Shaft speed 92.0 RPM, actual output torque 1120.5 N·m, mechanical shaft power 10.79 kW.
Auto-populates typical efficiencies
Industrial Machine Application Seeds

% (Internal Leakage Loss)
% (Frictional Drag Loss)
Torque:
Power:
Actual Output Torque (T_act)
1120.5 N·m
Theoretical: 1273.2 N·mT_th × η_m
Shaft Speed (n)
92.0 RPM
Volumetric Speed Slipn_th × η_v
Mechanical Power (P_mech)
10.79 kW
Hydraulic In: 13.33 kWT × n / 9549
Overall Efficiency (η_tot)
81.0%
Heat Loss: 2.54 kWη_v × η_m

Thermal Heat Dissipation & Mechanical Friction Budget

Loss: 2.54 kW
Useful Shaft Output: 10.79 kW (81.0%)
Thermal Heat Load: 2.54 kW (19.0%)
ISO 4391 Motor Power Flow & Heat Dissipation Balance
P_mech = P_hyd − Q_heat (η_tot = 81.0%)
Hydraulic Input (P_hyd)13.3 kWQ × ΔP / 600HydraulicMotorη_v × η_mThermal Heat Loss (Q_heat)2.5 kW (Slip & Friction)Mechanical Shaft Power (P_mech)10.8 kW · 92 RPMT_act = 1120 N·m (P = T×n / 9549)

Power flow diagram per ISO 4391: Supplied hydraulic fluid energy is split between usable mechanical shaft power (P_mech) and thermal dissipation (Q_heat). Internal case drain leakage and hydrodynamic seal friction generate continuous heat that must be dissipated by the machine hydraulic cooler.

SCOPED OEM MANUAL ASSISTANT

Prevent Premature Motor Stalling, Cavitation & $8,500 Final Drive Failures

An undersized hydraulic motor will overheat and fail within 200–500 operating hours when forced beyond its continuous torque and pressure rating (Parker Hydraulic Motor Handbook). Rigovely indexes factory shop manuals, displacement curves, and case drain specs for your specific machine serial number.

ISO 4391

Industrial Hydraulic Motor Characteristic Reference Matrix

Industry benchmark technical specifications across orbital, bent-axis axial piston, swashplate, radial piston, and gear motors with typical volumetric and mechanical efficiency ranges.

Heavy Equipment Hydraulic Motor Characteristic Reference Matrix

Industry design data per ISO 4391, ISO 8426, Parker Hannifin HY30-3250-M1, and Danfoss Motor Manual.

Motor Architecture Displacement (cc/rev) Max Press. (bar) Speed Range (RPM) Typ. η_v Typ. η_m Primary ApplicationAction
Orbital Gerotor / Geroller (Danfoss OMR / OMS / Eaton Char-Lynn)50 – 800200 / 250150 – 80092%86%Mobile Conveyors, Small Winches, Drilling Augers, Brush Cutters
Axial Piston Bent-Axis (Bosch Rexroth A2FM / Parker F12)10 – 1000350 / 4501500 – 450096%92%Excavator Swing Drives, Track Travel Drives, Forestry Harvester Saws
Axial Piston Swashplate Variable (Bosch Rexroth A6VM / Danfoss Series 51)28 – 250350 / 4002000 – 400095%90%Hydrostatic Wheel Loader Drives, Telehandlers, Compact Rollers
Radial Piston Multi-Stroke Cam-Lobe (Poclain MS / Rexroth MCR)250 – 15000400 / 45050 – 35097%94%Direct Wheel Hub Drive, Trenchers, Drum Cutters, Mining Haul Trucks
External Gear Motor (Parker PGM / Marzocchi GHP / Casappa Polaris)10 – 100200 / 2501000 – 300088%84%Hydraulic Radiator Cooling Fan Drive, Auxiliary Spreaders, Lube Pumps
GOVERNING STANDARDS

Hydraulic Motor Engineering Mechanics & Physics Derivations

Understand how internal volumetric leakage reduces actual shaft rotational speed, why hydrodynamic shear discounts theoretical torque, and how to balance fluid power against mechanical output and thermal cooling capacity.

1. Shaft Rotational Speed & Internal Slip
n = (Q × 1,000 / V_d) × η_v  [RPM]

In a hydraulic motor, fluid slipping across the high-pressure port to case drain bypass does not contribute to rotating the group. Therefore, actual shaft rotational speed (n) is the theoretical speed discounted by volumetric efficiency (η_v), contrasting directly with pumps where volumetric leakage reduces effective flow output.

2. Theoretical & Actual Shaft Torque
T_act = [(V_d × ΔP) / (20 × π)] × η_m  [N·m]

Theoretical torque is generated by the pressure drop (ΔP in bar) acting across the displacement volume per radian (V_d / 2π). Hydrodynamic shear in bearing journals and seal friction reduce this torque by mechanical efficiency (η_m).

3. Power Conservation & Overall Efficiency
P_hyd = (Q × ΔP) / 600  [kW]
P_mech = (T_act × n) / 9549.3  [kW]

Total overall efficiency is the composite product of volumetric and mechanical-hydraulic efficiency:η_tot = η_v × η_m. Shaft output power divided by hydraulic input power equals η_tot.

4. Waste Heat Generation (Thermal Budget)
Q_heat = P_hyd − P_mech = P_hyd × (1 − η_tot)  [kW]

Energy not converted to mechanical rotation transforms directly into heat within the fluid. If waste heat exceeds 15 kW, active forced-air or shell-and-tube heat exchangers and flushing case drain loops are mandated to preserve oil film thickness.

Field Engineering Worked Example: Mining Excavator Slew Motor

A 35-ton hydraulic excavator operates an axial piston bent-axis swing motor (Bosch Rexroth A2FM 107 cc). Main pump delivers 180 L/min at relief pressure 350 bar. Per catalog test curves, η_v = 96% and η_m = 92%:

  • n = (180 × 1000 / 107) × 0.96 = 1,614.9 RPM (shaft rotational speed)
  • T_th = (107 × 350) / (20 × π) = 596.0 N·m
  • T_act = 596.0 × 0.92 = 548.3 N·m (actual torque delivered to planetary swing gearbox)
  • P_hyd = (180 × 350) / 600 = 105.0 kW
  • P_mech = (548.3 × 1614.9) / 9549.3 = 92.7 kW
  • η_tot = 0.96 × 0.92 = 88.32%
  • Q_heat = 105.0 − 92.7 = 12.3 kW thermal load to machine oil cooler

Hydraulic Motor Frequently Asked Questions

Frequently Asked Engineering Questions (Hydraulic Motor Sizing & Troubleshooting)

What is the difference between theoretical torque and actual torque in a hydraulic motor?

Theoretical torque (T_th = V_d × ΔP / 20π) assumes 100% frictionless fluid-to-shaft conversion. Actual output torque (T_act = T_th × η_m) accounts for mechanical drag from piston slippers, rotor vanes, hydrodynamic journal bearings, and shaft seals. Typical mechanical efficiency (η_m) ranges from 82% to 94% depending on motor architecture.

Why does volumetric efficiency reduce motor speed while reducing pump flow?

In a hydraulic pump, internal leakage reduces output flow delivered to the circuit. In a hydraulic motor, fluid slipping across internal clearances bypasses the working chambers directly to the case drain without causing displacement rotation. Consequently, actual shaft speed equals theoretical speed multiplied by volumetric efficiency: n = (Q × 1,000 / V_d) × η_v.

How do you size a hydraulic motor for a target torque and shaft speed?

First calculate minimum displacement: V_d,req = (T_target × 20π) / (ΔP × η_m). Then compute required supply flow from the pump: Q_req = (n_target × V_d,req) / (1,000 × η_v). Select the next standard commercial motor frame size and verify the operating pressure remains below continuous catalog ratings.

When is a dedicated external case drain line required on a hydraulic motor?

Whenever motor return line backpressure exceeds shaft seal limits (typically 5 to 20 bar on orbital motors, 2 to 5 bar on piston motors) or during high-pressure bidirectional closed-loop hydrostatic drives. Connecting the case drain directly to tank prevents blowing the high-pressure shaft seal and provides continuous cooling flush.

What happens if an orbital gerotor motor is operated beyond 800 RPM?

Orbital gerotor motors are low-speed high-torque (LSHT) units. Exceeding 800 RPM induces severe cavitation across the distributor valve spool, accelerated orbiting star friction, excessive case temperature exceeding 90°C, and rapid hydraulic chatter that destroys seals within 200–500 operational hours.

Shop bench

Free shop calculators grounded in published standards (Parker Catalog 4300, SAE J1939, AS568). They run in the browser with no login and no paywall.

Need the Exact Factory Schematic or Torque Table for This Machine?

Stop scrolling through 1,200 to 4,000-page OEM PDFs on a phone screen. Upload your shop's Service and Test & Adjust manuals into Rigovely's isolated Scoped OEM Index. The Beta diagnostic co-pilot pinpoints the wiring pinout, relief pressure, or torque sequence by S/N prefix alongside Fleetio, SAP, or Maximo.

100% Shop-Controlled Library: Your internal manuals are encrypted and never used to train public AI models.Start 7-Day Free Trial - Upload Your Shop PDFs
View All Free Tools
Shop Downtime & ROI Scenario Calculator
01 · Fleet & Shop Economics

Shop Downtime & ROI Scenario Calculator

Model technician manual search friction, wrong-part restocking penalties, and independent equipment downtime using your shop’s actual repair order volume.

  • SMRP Metric 5.6.1
  • USACE EP 1110-1-8
  • Multi-Currency ROI
AS568 Hydraulic O-Ring Size & Nominal Gland Calculator
02 · SAE AS568 · Parker 2-xxx

AS568 Hydraulic O-Ring Size & Nominal Gland Calculator

Identify standard AS568 dash numbers and Parker 2-xxx designations from caliper ID and CS measurements with tolerance overlap and rectangular gland fill math.

  • SAE AS568 Rev D
  • Parker ORD 5700
  • 2D Interval Overlap
Hydraulic Fitting Torque & Thread Reference
03 · JIC 37° · ORFS · SAE ORB

Hydraulic Fitting Torque & Thread Reference

Look up thread designations, sealing mechanisms, and manufacturer assembly conditions for JIC 37° flare, ORFS face seal, and SAE O-ring boss connections.

  • SAE J514 · J1453
  • SAE J1926-1 ORB
  • No 0.75× Multipliers
Fastener Preload & Bolt Torque Calculator (T = K × F × d)
04 · ISO 898-1 · SAE J429

Fastener Preload & Bolt Torque Calculator (T = K × F × d)

Calculate tensile stress area (As), proof load, target clamp preload (F), and tightening torque (T = K × F × d) with explicit nut factor K and anti-seize yield risk simulation.

  • ISO 898-1 Class 8.8/10.9/12.9
  • SAE J429 Grade 5/8
  • Bossard F-047
SAE J1939 Fault Code (SPN/FMI) & Deutsch 9-Pin Reference
05 · SAE J1939-73 · Deutsch 9-Pin

SAE J1939 Fault Code (SPN/FMI) & Deutsch 9-Pin Reference

Decode 5-bit Failure Mode Identifiers (FMI 0–31), curated Suspect Parameter Numbers (SPN), proprietary OEM SPN ranges, and Deutsch HD10-9-1939 9-pin connector cavities.

  • SAE J1939-73 FMI 0–31
  • Deutsch HD10-9-1939
  • Gateway Guardrails
SAE J518 4-Bolt Split Flange (Code 61 / Code 62 / CAT) Calculator
06 · SAE J518 · Parker 4300 T6

SAE J518 4-Bolt Split Flange (Code 61 / Code 62 / CAT) Calculator

Match caliper flange head OD, thickness, and bolt pattern to SAE Code 61, Code 62, or Caterpillar 14.22 mm (0.560") high-pressure flanges with AS568 O-ring and 3-step cross-bolt torque specs.

  • SAE J518 / ISO 6162
  • Code 62 vs CAT 14.22 mm
  • Parker Table T6