Last Updated: November 2, 2026
SAE J1939 Fault Code (SPN / FMI) & Deutsch 9-Pin Diagnostic Reference
SAE J1939 diagnostic trouble codes pair a 19-bit Suspect Parameter Number (SPN 1–524,287) with a 5-bit Failure Mode Identifier (FMI 0–31) to distinguish physical out-of-range conditions (FMI 0–1, 15–18) from electrical circuit opens/shorts (FMI 3–6) and CAN data link dropouts (FMI 2, 9, 19).
Interactive SAE J1939 SPN and FMI Fault Code Lookup
1. Explicit SPN & FMI Lookup Inputs
Enter SPN and FMI separately, or leave either field blank for single-axis lookup.
97.03? Some display monitors use dot notation for J1939 SPN.FMI, while other brands display proprietary event codes (`E361-3`, `CA234`). Explicit fields prevent silent mis-mapping.SAE J1939 SPN & FMI Diagnostic Lookup Output
SPN 639 · FMI 2
SAE J1939 Network #1 (Primary Vehicle CAN Data Link) — Data Erratic, Intermittent or Incorrect
SAE J1939 Network #1 (Primary Vehicle CAN Data Link)
Primary SAE J1939 twisted-pair CAN bus data link connecting engine, transmission, machine cab, and aftertreatment ECUs.
FMI 2 — Data Erratic, Intermittent or Incorrect
The signal changes faster than physically possible, drops out intermittently, or fails rationality cross-checks against secondary sensors (e.g., crank vs. cam speed or key-on static pressure check).
- Frequently caused by loose terminal fretting, moisture ingress in connectors, or CAN data link frame dropouts.
- Never back-probe or apply external test voltage without verifying the exact ECM pinout and sensor architecture (passive 2-wire thermistor, active 5V 3-wire hall/piezo, or 4-wire CAN smart sensor) in the machine schematic.
Passive 2-wire thermistors, active 3-wire 5V hall/piezo sensors, and 4-wire CAN smart sensors (NOx/DPF modules) use fundamentally different voltage architectures. Never probe or jumper ECM harness pins without the exact machine wiring schematic for your serial number.
Source: U.S. NHTSA Public Technical Service Bulletin Repository / Cummins & Bendix J1939 Diagnostic Reference · NHTSA / Cummins & Bendix Public Heavy-Duty Diesel SAE J1939 Suspect Parameter Number (SPN) & Multiplexing Cross-Reference Bulletin (NHTSA OEM Service Bulletin Compendium (MC-10186829 / SD-13-48699) — Reviewed 2026-11-02) — Table: Curated 19-Bit Suspect Parameter Number (SPN) Standard Assignments (SPNs 27–5246) & Proprietary Manufacturer Boundary (SPN 520,192–524,287). Reviewed 2026-11-02 by Rigovely Technical Review Team.
Source: Bendix Commercial Vehicle Systems / Cummins Service Engineering Reference (SAE J1939-73 Public Summary) · Bendix / Cummins Heavy-Duty SAE J1939-73 Diagnostic Troubleshooting & Failure Mode Identifier (FMI 0–31) Service Reference (SD-13-48699) (Bendix Service Data Sheet SD-13-48699 Rev. 011 / Heavy-Duty J1939 Diagnostic Guide (Reviewed 2026-11-02)) — Section: SAE J1939 Diagnostic Trouble Code (DTC) Structure — Table of 5-Bit Failure Mode Identifiers (FMI 0 through FMI 31) & Circuit Signal Classifications. Reviewed 2026-11-02 by Rigovely Technical Review Team.
Need Exact ECM Pinouts & Wiring Schematics From Your OEM Service Manual?
Decoding an SPN and FMI tells you what circuit or parameter failed—but isolating the wire requires the exact ECM connector pinout, harness color code, and troubleshooting tree for that machine’s serial number. Rigovely searches the PDF manuals your shop already owns and opens the cited schematic page.
100% browser-local lookup. Your fault code queries and machine details are never sent to analytics.
Deutsch 9-Pin (SAE J1939-13 / HD10-9-1939) Diagnostic Connector Pinout
The standard heavy-duty Deutsch 9-pin diagnostic receptacle assigns Pin A to battery ground, Pin B to +12V/+24V power, Pin C to J1939 CAN High (+), and Pin D to J1939 CAN Low (−), while housing color and Pin F keyway distinguish Type 1 Black (250 kbps) from Type 2 Green (500 kbps).
Critical Diagnostic Guardrail: Why Passive 60 Ω / 120 Ω Readings at Pins C & D Can Mislead on Gateway Machines
On a classical unbuffered SAE J1939-11 backbone with two parallel 120 Ω terminating resistors (key-off, batteries disconnected), measuring between Pin C and Pin D yields roughly 60 Ω (~120 Ω if one terminator is open). However, on modern Tier 4 Final / Stage V heavy equipment, the cab 9-pin diagnostic port is frequently isolated behind a Central Gateway Module. Reading >1,000 Ω or 120 Ω at the cab port does not automatically prove a broken engine CAN backbone, and passive DC resistance never detects a CAN wire shorted to ground/battery or a failed ECU transceiver.
Pin A — Battery Negative (−) / Ground
Pin B — Battery Positive (+) / Unswitched or Ignition Power
Pin C — CAN 1 High — SAE J1939_11 Data Link (+)
Pin D — CAN 1 Low — SAE J1939_11 Data Link (−)
Pin E — CAN 1 Shield / Drain
Pin F — SAE J1708 (+) or Secondary /OEM Network (Keyed Cavity)
Pin G — SAE J1708 (−) or Secondary / OEM Network
Pin H — OEM Proprietary / Secondary CAN High (CAN 2 + / Implement Bus)
Pin J — OEM Proprietary / Secondary CAN Low (CAN 2 − / Implement Bus)
Source: TE Connectivity (Industrial & Commercial Transportation / DEUTSCH) — DEUTSCH HD10 Series 9-Pin Diagnostic Connectors (HD10-9-1939P Type 1 Black & HD10-9-1939P-P080 Type 2 Green) Product Specification & SAE J1939-13 Cavity Assignment (TE Catalog ICT / SAE J1939-13 Off-Board Diagnostic Connector Reference (2024)). Reviewed 2026-11-02 by Rigovely Technical Review Team.
SAE J1939 Failure Mode Identifier (FMI 0–31) Reference Table
FMI codes 0, 1, and 15–18 indicate valid sensor data that has crossed an operating threshold, whereas FMI 3, 4, 5, and 6 indicate electrical circuit shorts or opens at the ECU input or driver stage.
FMI 0 — Data Valid But Above Normal Operational Range — Most Severe Level
The sensor signal is electrically valid (not shorted or open), but the measured physical parameter (such as coolant temperature or fuel rail pressure) exceeds the critical upper operating limit.
FMI 1 — Data Valid But Below Normal Operational Range — Most Severe Level
The sensor signal is within valid electrical bounds, but the physical reading (such as engine oil pressure or coolant level) has dropped below the critical minimum threshold.
FMI 2 — Data Erratic, Intermittent or Incorrect
The signal changes faster than physically possible, drops out intermittently, or fails rationality cross-checks against secondary sensors (e.g., crank vs. cam speed or key-on static pressure check).
FMI 3 — Voltage Above Normal, or Shorted to High Source
Signal voltage at the ECU input pin exceeds the maximum sensor design threshold (often >4.8V on a 5V reference circuit), indicating a short to 5V/12V/24V supply or an open ground/pull-up circuit.
FMI 4 — Voltage Below Normal, or Shorted to Low Source
Signal voltage at the ECU input pin has fallen below the minimum valid floor (often <0.2V on a 0.5V–4.5V analog sensor), indicating a short to chassis ground, sensor return, or loss of 5V reference supply.
FMI 5 — Current Below Normal or Open Circuit
Current flow through an actuator driver circuit (such as a fuel injector solenoid, hydraulic proportional valve, or relay coil) is below the minimum expected threshold, typically due to an open wire, corroded pin, or burned coil.
FMI 6 — Current Above Normal or Grounded Circuit
Current draw on an ECU output driver exceeds the safe threshold, indicating a short circuit between the high-side driver and ground or a shorted actuator solenoid coil.
FMI 7 — Mechanical System Not Responding or Out of Adjustment
The ECU commands an actuator (such as a VGT turbo actuator, EGR valve, fuel rail pressure control valve, or shift solenoid), but closed-loop position or pressure feedback does not match the target command.
FMI 8 — Abnormal Frequency or Pulse Width or Period
Signal frequency, PWM duty cycle, or pulse period is outside expected bounds (common on PWM throttle pedals, speed sensors, or digital smart sensors).
FMI 9 — Abnormal Update Rate
A J1939 CAN bus message or smart sensor frame (e.g., NOx sensor, VGT module, or transmission controller) was not received by the ECU within the expected broadcast interval.
Source: SAE J1939-73 Application Layer Diagnostics & Public Heavy-Duty J1939 Reference (Reviewed 2026-11-02).
Curated High-Frequency SAE J1939 SPN Parameter Reference Table
Core standard SPNs—such as SPN 100 (Engine Oil Pressure), SPN 110 (Coolant Temperature), SPN 639 (J1939 Network #1), and SPN 3226 (Aftertreatment Outlet NOx)—identify the monitored subsystem across mixed heavy equipment fleets.
SPN 91 — Accelerator Pedal Position 1
Primary operator throttle/accelerator position signal input (percentage of full travel) to the engine or machine controller.
SPN 94 — Engine Fuel Delivery Pressure
Low-pressure fuel transfer/lift pump supply pressure measured upstream of the high-pressure common-rail injection pump.
SPN 97 — Water in Fuel Indicator 1
Conductivity/capacitance probe in the primary fuel-water separator bowl detecting accumulated water in diesel fuel.
SPN 100 — Engine Oil Pressure
Main rifle engine lubricating oil gallery pressure monitored for engine protection and low-oil-pressure shutdown.
SPN 102 — Engine Intake Manifold #1 Pressure (Boost Pressure)
Positive gauge pressure in the intake manifold downstream of the turbocharger and charge-air cooler.
SPN 105 — Engine Intake Manifold #1 Temperature
Charge-air temperature entering the engine intake manifold after the aftercooler/intercooler.
SPN 110 — Engine Coolant Temperature
Engine block/thermostat housing coolant temperature used for thermal protection, fan control, and cold-start fueling.
SPN 111 — Engine Coolant Level 1
Surge tank / radiator top-tank coolant level switch or probe monitoring for coolant loss.
SPN 157 — Engine Injector Metering Rail 1 Pressure
High-pressure common-rail (HPCR) fuel accumulator pressure measured for closed-loop injection control.
SPN 168 — Electrical Potential / Battery Potential (Power Input 1)
Main unswitched battery supply voltage (+12V or +24V nominal) measured at the ECM power input pins.
Source: Curated SAE J1939 Standard Parameter Reference (Reviewed 2026-11-02). Proprietary OEM range: SPN 520,192–524,287.
Free Standards-Grounded J1939 Decoding + BYOD Manual Search vs. Metered AI Sessions
Why spend $12.95 to $99/month on AI Diesel Tech for 3 to 60 metered fault-tree sessions? Pair Rigovely’s 100% free SAE J1939 SPN/FMI decoder with flat-rate $49/mo Beta manual search to inspect factory wiring and troubleshooting procedures with zero session caps.
How SAE J1939 SPN and FMI Bit-Packing Works
Every SAE J1939-73 Diagnostic Trouble Code (DTC) packs a 19-bit Suspect Parameter Number (SPN 1–524,287) with a 5-bit Failure Mode Identifier (FMI 0–31) inside a 4-byte Diagnostic Message (DM1 active / DM2 previously active).
Worked Example: SPN 110 FMI 0 vs. SPN 110 FMI 3
Both fault codes point to SPN 110 (Engine Coolant Temperature), but the 5-bit FMI completely changes the technician’s first diagnostic action:
1. SPN 110 · FMI 0 (Data Valid Above Normal — Most Severe): Sensor signal is within valid electrical bounds; engine coolant is physically overheating. Inspect coolant level, radiator core restriction, water pump, and fan drive.
2. SPN 110 · FMI 3 (Voltage Above Normal / Shorted to High): Input voltage at the ECM exceeds the analog ceiling (~4.95V). On a 2-wire NTC thermistor with an internal ECM 5V pull-up resistor, an unplugged connector or broken wire causes FMI 3.
1. 2-Wire Passive vs. 3-Wire Active 5V vs. 4-Wire Smart CAN Sensors
Generic online fault code lists often instruct mechanics to “check for 5V or 12V/24V at the sensor plug” regardless of parameter. On modern heavy equipment, applying external test voltage or probing the wrong terminal can destroy an ECM driver:
- 2-Wire NTC Thermistor (e.g. Coolant / Oil Temp): Uses internal ECM 5V pull-up; open circuit reads ~5.0V (sets FMI 3), shorted wire reads ~0.0V (sets FMI 4).
- 3-Wire Active Hall / Piezo Pressure Sensor (e.g. Rail / Boost Pressure): Uses 5V reference, return ground, and 0.5V–4.5V signal; broken signal wire typically pulls low (<0.2V, setting FMI 4).
- 4-Wire CAN Smart Sensor (e.g. SPN 3216 / 3226 NOx Module): Connects to battery +12V/+24V, ground, and J1939 CAN High/Low; communicates digitally (often logs FMI 2, 9, 12, or 19).
2. Standard SPNs vs. Proprietary Manufacturer Range (520,192–524,287)
Under SAE J1939-73 (Bendix SD-13-48699 Reference) and TE Connectivity DEUTSCH HD10-9-1939, the 19-bit SPN space reserves integers 520,192 through 524,287 for OEM-proprietary assignment.
When a machine monitor displays a proprietary SPN (or an OEM-specific event code), the 5-bit FMI (0–31) still follows the standard electrical/operational classification, but the component identity must be verified in the OEM service manual for that exact model and serial number prefix.
Mechanical and Hydraulic Checks After the Sensor
When an active code logs FMI 0, FMI 1, FMI 7, or FMI 15–18 on a pressure or fluid-level parameter, the electrical sensor loop is reporting a real hydraulic or mechanical anomaly.
If your inspection uncovers a weeping pressure transducer port, damaged O-ring face seal, or loose manifold bracket, use our Hydraulic Fitting Torque & Thread Reference for JIC 37°, ORFS, and SAE O-Ring Boss port assembly specs, our AS568 Hydraulic O-Ring Size & Caliper Matcher to identify replacement boss seals, or our Fastener Preload & Bolt Torque Calculator for mounting hardware.
Comparing Free J1939 SPN/FMI Decoding vs. Metered AI Diagnostic Sessions?
See how Rigovely’s free SAE J1939 decoder + flat $49/mo BYOD manual search compares against AI Diesel Tech’s $12.95–$199/mo metered sessions and 6 alternatives.
Hitting 50-Credit Monthly Caps Looking Up J1939 Fault Trees & Schematics?
See how Rigovely’s unlimited BYOD manual retrieval + free J1939 decoder compares against Diesel Repair ($9.99–$249.99/mo), Noregon NextStep, and Cojali Jaltest OHW.
Using a Multi-Brand VCI Scanner on 9-Pin J1939 Off-Highway Ports?
Using a multi-brand VCI scanner on 9-pin J1939 off-highway ports? Compare Rigovely vs. Cojali Jaltest OHW or review the 6 Best Jaltest OHW Alternatives for 2026.
Decoded a fault code and need the exact wiring pinout across a mixed fleet?
Compare Rigovely vs. Cat SIS 2.0 & SIS2GO and review the 6 Best Cat SIS 2.0 Alternatives for 2026.
Decoded a monitor abnormality code and need physical ECM bi-directional testing?
Related Free Heavy Equipment Shop Tools
Free shop calculators grounded in published standards (Parker Catalog 4300, SAE J1939, AS568). They run in the browser with no login and no paywall.
Need the Exact Factory Schematic or Torque Table for This Machine?
Stop scrolling through 1,200 to 4,000-page OEM PDFs on a phone screen. Upload your shop's Service and Test & Adjust manuals into Rigovely's isolated Scoped OEM Index. The Beta diagnostic co-pilot pinpoints the wiring pinout, relief pressure, or torque sequence by S/N prefix alongside Fleetio, SAP, or Maximo.
100% Shop-Controlled Library: Your internal manuals are encrypted and never used to train public AI models.Start 7-Day Free Trial - Upload Your Shop PDFs
Shop Downtime & ROI Scenario Calculator
Model technician manual search friction, wrong-part restocking penalties, and independent equipment downtime using your shop’s actual repair order volume.
- SMRP Metric 5.6.1
- USACE EP 1110-1-8
- Multi-Currency ROI

AS568 Hydraulic O-Ring Size & Nominal Gland Calculator
Identify standard AS568 dash numbers and Parker 2-xxx designations from caliper ID and CS measurements with tolerance overlap and rectangular gland fill math.
- SAE AS568 Rev D
- Parker ORD 5700
- 2D Interval Overlap

Hydraulic Fitting Torque & Thread Reference
Look up thread designations, sealing mechanisms, and manufacturer assembly conditions for JIC 37° flare, ORFS face seal, and SAE O-ring boss connections.
- SAE J514 · J1453
- SAE J1926-1 ORB
- No 0.75× Multipliers

Fastener Preload & Bolt Torque Calculator (T = K × F × d)
Calculate tensile stress area (As), proof load, target clamp preload (F), and tightening torque (T = K × F × d) with explicit nut factor K and anti-seize yield risk simulation.
- ISO 898-1 Class 8.8/10.9/12.9
- SAE J429 Grade 5/8
- Bossard F-047

SAE J518 4-Bolt Split Flange (Code 61 / Code 62 / CAT) Calculator
Match caliper flange head OD, thickness, and bolt pattern to SAE Code 61, Code 62, or Caterpillar 14.22 mm (0.560") high-pressure flanges with AS568 O-ring and 3-step cross-bolt torque specs.
- SAE J518 / ISO 6162
- Code 62 vs CAT 14.22 mm
- Parker Table T6

Hydraulic Cylinder Push/Pull Force, Cycle Time & Intensification Calculator
Calculate double-acting cylinder push and pull force, cycle time, oil volume, and rod-end pressure spike when the return port is blocked.
- ISO 3320 Bore/Rod
- Rod-End Pressure Spike
- Single / Twin Cylinders