SAE J1939-73

Last Updated: November 2, 2026

SAE J1939 Fault Code (SPN / FMI) & Deutsch 9-Pin Diagnostic Reference

SAE J1939 diagnostic trouble codes pair a 19-bit Suspect Parameter Number (SPN 1–524,287) with a 5-bit Failure Mode Identifier (FMI 0–31) to distinguish physical out-of-range conditions (FMI 0–1, 15–18) from electrical circuit opens/shorts (FMI 3–6) and CAN data link dropouts (FMI 2, 9, 19).

Direct Specification Summary · SAE J1939-73 & SAE J1939-13 (HD10-9-1939)In SAE J1939-73 diagnostics, the SPN identifies the subsystem or sensor while the FMI (0–31) defines the fault type: FMI 3 and FMI 4 indicate electrical wiring shorts to high/open or ground, whereas FMI 0, 1, 15–18 indicate real physical operating extremes. On a Deutsch 9-pin connector, Pins C (CAN_H) and D (CAN_L) should measure 60 Ω key-off across two 120 Ω terminating resistors.

Interactive SAE J1939 SPN and FMI Fault Code Lookup

Decoded SPN 639 SAE J1939 Network #1 (Primary Vehicle CAN Data Link), FMI 2 Data Erratic, Intermittent or Incorrect.

1. Explicit SPN & FMI Lookup Inputs

Enter SPN and FMI separately, or leave either field blank for single-axis lookup.

19-Bit Range: 1 – 524,287
5-Bit Range: 0 – 31
Common Workshop SPN/FMI Diagnostic Queries:
Why separate SPN and FMI inputs instead of auto-splitting 97.03? Some display monitors use dot notation for J1939 SPN.FMI, while other brands display proprietary event codes (`E361-3`, `CA234`). Explicit fields prevent silent mis-mapping.

SAE J1939 SPN & FMI Diagnostic Lookup Output

Verified SPN + FMI Diagnostic Match

SPN 639 · FMI 2

SAE J1939 Network #1 (Primary Vehicle CAN Data Link) — Data Erratic, Intermittent or Incorrect

Suspect Parameter Number (SPN 639)CAN Network & Data Link

SAE J1939 Network #1 (Primary Vehicle CAN Data Link)

Primary SAE J1939 twisted-pair CAN bus data link connecting engine, transmission, machine cab, and aftertreatment ECUs.

OEM Calibration & Wiring Note: Frequently searched as SPN 639 FMI 2, FMI 9, or FMI 14. Check which Source Address (SA) logged the timeout and verify gateway architecture before measuring passive bus resistance.
Failure Mode Identifier (FMI 2)Erratic, Intermittent or Implausible Data

FMI 2 — Data Erratic, Intermittent or Incorrect

The signal changes faster than physically possible, drops out intermittently, or fails rationality cross-checks against secondary sensors (e.g., crank vs. cam speed or key-on static pressure check).

Anti-Misdiagnosis Scope Boundaries:
  • Frequently caused by loose terminal fretting, moisture ingress in connectors, or CAN data link frame dropouts.
  • Never back-probe or apply external test voltage without verifying the exact ECM pinout and sensor architecture (passive 2-wire thermistor, active 5V 3-wire hall/piezo, or 4-wire CAN smart sensor) in the machine schematic.
Primary Source Provenance & Electrical Safety Guardrail

Passive 2-wire thermistors, active 3-wire 5V hall/piezo sensors, and 4-wire CAN smart sensors (NOx/DPF modules) use fundamentally different voltage architectures. Never probe or jumper ECM harness pins without the exact machine wiring schematic for your serial number.

Source: U.S. NHTSA Public Technical Service Bulletin Repository / Cummins & Bendix J1939 Diagnostic Reference · NHTSA / Cummins & Bendix Public Heavy-Duty Diesel SAE J1939 Suspect Parameter Number (SPN) & Multiplexing Cross-Reference Bulletin (NHTSA OEM Service Bulletin Compendium (MC-10186829 / SD-13-48699) — Reviewed 2026-11-02) — Table: Curated 19-Bit Suspect Parameter Number (SPN) Standard Assignments (SPNs 27–5246) & Proprietary Manufacturer Boundary (SPN 520,192–524,287). Reviewed 2026-11-02 by Rigovely Technical Review Team.

Source: Bendix Commercial Vehicle Systems / Cummins Service Engineering Reference (SAE J1939-73 Public Summary) · Bendix / Cummins Heavy-Duty SAE J1939-73 Diagnostic Troubleshooting & Failure Mode Identifier (FMI 0–31) Service Reference (SD-13-48699) (Bendix Service Data Sheet SD-13-48699 Rev. 011 / Heavy-Duty J1939 Diagnostic Guide (Reviewed 2026-11-02)) — Section: SAE J1939 Diagnostic Trouble Code (DTC) Structure — Table of 5-Bit Failure Mode Identifiers (FMI 0 through FMI 31) & Circuit Signal Classifications. Reviewed 2026-11-02 by Rigovely Technical Review Team.

Scoped OEM Manual Assistant

Need Exact ECM Pinouts & Wiring Schematics From Your OEM Service Manual?

Decoding an SPN and FMI tells you what circuit or parameter failed—but isolating the wire requires the exact ECM connector pinout, harness color code, and troubleshooting tree for that machine’s serial number. Rigovely searches the PDF manuals your shop already owns and opens the cited schematic page.

100% browser-local lookup. Your fault code queries and machine details are never sent to analytics.

TE Connectivity DEUTSCH

Deutsch 9-Pin (SAE J1939-13 / HD10-9-1939) Diagnostic Connector Pinout

The standard heavy-duty Deutsch 9-pin diagnostic receptacle assigns Pin A to battery ground, Pin B to +12V/+24V power, Pin C to J1939 CAN High (+), and Pin D to J1939 CAN Low (−), while housing color and Pin F keyway distinguish Type 1 Black (250 kbps) from Type 2 Green (500 kbps).

Critical Diagnostic Guardrail: Why Passive 60 Ω / 120 Ω Readings at Pins C & D Can Mislead on Gateway Machines

On a classical unbuffered SAE J1939-11 backbone with two parallel 120 Ω terminating resistors (key-off, batteries disconnected), measuring between Pin C and Pin D yields roughly 60 Ω (~120 Ω if one terminator is open). However, on modern Tier 4 Final / Stage V heavy equipment, the cab 9-pin diagnostic port is frequently isolated behind a Central Gateway Module. Reading >1,000 Ω or 120 Ω at the cab port does not automatically prove a broken engine CAN backbone, and passive DC resistance never detects a CAN wire shorted to ground/battery or a failed ECU transceiver.

A

Pin A — Battery Negative (−) / Ground

HD10-9-1939 APPROVED
Type 1 (250k): Unfused vehicle/machine battery ground return path for diagnostic adapter.Type 2 (500k): Unfused vehicle/machine battery ground return path for diagnostic adapter.
Cavity:Pin A
B

Pin B — Battery Positive (+) / Unswitched or Ignition Power

HD10-9-1939 APPROVED
Type 1 (250k): +12V or +24V DC nominal system supply (fused on machine side; verify voltage before connecting 12V-only accessories).Type 2 (500k): +12V or +24V DC nominal system supply (fused on machine side).
Cavity:Pin B
C

Pin C — CAN 1 High — SAE J1939_11 Data Link (+)

HD10-9-1939 APPROVED
Type 1 (250k): Primary J1939 CAN High data line operating at 250 kbps nominal baud rate (yellow wire in standard SAE J1939-11 twisted pair).Type 2 (500k): Primary J1939 CAN High data line operating at 500 kbps (or auto-negotiated 250/500 kbps depending on OEM gateway).
Cavity:Pin C
D

Pin D — CAN 1 Low — SAE J1939_11 Data Link (−)

HD10-9-1939 APPROVED
Type 1 (250k): Primary J1939 CAN Low data line operating at 250 kbps nominal baud rate (green wire in standard SAE J1939-11 twisted pair).Type 2 (500k): Primary J1939 CAN Low data line operating at 500 kbps (or auto-negotiated 250/500 kbps).
Cavity:Pin D
E

Pin E — CAN 1 Shield / Drain

HD10-9-1939 APPROVED
Type 1 (250k): Shield drain connection for shielded twisted-pair J1939-11 harnesses (unpopulated on unshielded J1939-15 twisted pair).Type 2 (500k): Shield drain connection (often unpopulated on unshielded J1939-15 harnesses).
Cavity:Pin E
F

Pin F — SAE J1708 (+) or Secondary /OEM Network (Keyed Cavity)

HD10-9-1939 APPROVED
Type 1 (250k): Standard circular keyway on black HD10-9-1939P housing; traditionally assigned to legacy SAE J1708/J1587 Data (+).Type 2 (500k): Modified narrow keyway on green HD10-9-1939P-P080 housing to block legacy 250k-only plugs; may carry J1708 (+) or OEM CAN channel.
Cavity:Pin F
G

Pin G — SAE J1708 (−) or Secondary / OEM Network

HD10-9-1939 APPROVED
Type 1 (250k): Traditionally assigned to legacy SAE J1708/J1587 Data (−) twisted pair return.Type 2 (500k): Legacy SAE J1708 (−) or repurposed by OEM for secondary diagnostic network.
Cavity:Pin G
H

Pin H — OEM Proprietary / Secondary CAN High (CAN 2 + / Implement Bus)

HD10-9-1939 APPROVED
Type 1 (250k): OEM proprietary signal (e.g., Caterpillar CDL High, ISO 11783 implement bus, or unpopulated).Type 2 (500k): Secondary J1939 CAN 2 High or OEM proprietary data link (e.g., CAT Data Link + / chassis CAN High).
Cavity:Pin H
J

Pin J — OEM Proprietary / Secondary CAN Low (CAN 2 − / Implement Bus)

HD10-9-1939 APPROVED
Type 1 (250k): OEM proprietary signal (e.g., Caterpillar CDL Low, ISO 11783 implement bus, or unpopulated). (Note: letter "I" is skipped to avoid confusion with "1".)Type 2 (500k): Secondary J1939 CAN 2 Low or OEM proprietary data link (e.g., CAT Data Link − / chassis CAN Low).
Cavity:Pin J

Source: TE Connectivity (Industrial & Commercial Transportation / DEUTSCH) — DEUTSCH HD10 Series 9-Pin Diagnostic Connectors (HD10-9-1939P Type 1 Black & HD10-9-1939P-P080 Type 2 Green) Product Specification & SAE J1939-13 Cavity Assignment (TE Catalog ICT / SAE J1939-13 Off-Board Diagnostic Connector Reference (2024)). Reviewed 2026-11-02 by Rigovely Technical Review Team.

SAE J1939-73 Application

SAE J1939 Failure Mode Identifier (FMI 0–31) Reference Table

FMI codes 0, 1, and 15–18 indicate valid sensor data that has crossed an operating threshold, whereas FMI 3, 4, 5, and 6 indicate electrical circuit shorts or opens at the ECU input or driver stage.

Filter by Signal / Circuit Classification:
0

FMI 0 — Data Valid But Above Normal Operational Range — Most Severe Level

The sensor signal is electrically valid (not shorted or open), but the measured physical parameter (such as coolant temperature or fuel rail pressure) exceeds the critical upper operating limit.

APPROVED
Physical Value Above Normal Range
FMI:0
1

FMI 1 — Data Valid But Below Normal Operational Range — Most Severe Level

The sensor signal is within valid electrical bounds, but the physical reading (such as engine oil pressure or coolant level) has dropped below the critical minimum threshold.

APPROVED
Physical Value Below Normal Range
FMI:1
2

FMI 2 — Data Erratic, Intermittent or Incorrect

The signal changes faster than physically possible, drops out intermittently, or fails rationality cross-checks against secondary sensors (e.g., crank vs. cam speed or key-on static pressure check).

APPROVED
Erratic, Intermittent or Implausible Data
FMI:2
3

FMI 3 — Voltage Above Normal, or Shorted to High Source

Signal voltage at the ECU input pin exceeds the maximum sensor design threshold (often >4.8V on a 5V reference circuit), indicating a short to 5V/12V/24V supply or an open ground/pull-up circuit.

APPROVED
Circuit Voltage High / Short to High Source
FMI:3
4

FMI 4 — Voltage Below Normal, or Shorted to Low Source

Signal voltage at the ECU input pin has fallen below the minimum valid floor (often <0.2V on a 0.5V–4.5V analog sensor), indicating a short to chassis ground, sensor return, or loss of 5V reference supply.

APPROVED
Circuit Voltage Low / Short to Ground
FMI:4
5

FMI 5 — Current Below Normal or Open Circuit

Current flow through an actuator driver circuit (such as a fuel injector solenoid, hydraulic proportional valve, or relay coil) is below the minimum expected threshold, typically due to an open wire, corroded pin, or burned coil.

APPROVED
Current Low / Open Circuit Resistance
FMI:5
6

FMI 6 — Current Above Normal or Grounded Circuit

Current draw on an ECU output driver exceeds the safe threshold, indicating a short circuit between the high-side driver and ground or a shorted actuator solenoid coil.

APPROVED
Current High / Shorted Load Circuit
FMI:6
7

FMI 7 — Mechanical System Not Responding or Out of Adjustment

The ECU commands an actuator (such as a VGT turbo actuator, EGR valve, fuel rail pressure control valve, or shift solenoid), but closed-loop position or pressure feedback does not match the target command.

APPROVED
Mechanical System Not Responding / Out of Calibration
FMI:7
8

FMI 8 — Abnormal Frequency or Pulse Width or Period

Signal frequency, PWM duty cycle, or pulse period is outside expected bounds (common on PWM throttle pedals, speed sensors, or digital smart sensors).

APPROVED
Abnormal Frequency, Pulse Width, or CAN Update Rate
FMI:8
9

FMI 9 — Abnormal Update Rate

A J1939 CAN bus message or smart sensor frame (e.g., NOx sensor, VGT module, or transmission controller) was not received by the ECU within the expected broadcast interval.

APPROVED
Abnormal Frequency, Pulse Width, or CAN Update Rate
FMI:9
Showing 1 to 10 of 32 records

Source: SAE J1939-73 Application Layer Diagnostics & Public Heavy-Duty J1939 Reference (Reviewed 2026-11-02).

Curated Heavy-Duty SPN

Curated High-Frequency SAE J1939 SPN Parameter Reference Table

Core standard SPNs—such as SPN 100 (Engine Oil Pressure), SPN 110 (Coolant Temperature), SPN 639 (J1939 Network #1), and SPN 3226 (Aftertreatment Outlet NOx)—identify the monitored subsystem across mixed heavy equipment fleets.

Filter by Machine Subsystem:

SPN 91 — Accelerator Pedal Position 1

Primary operator throttle/accelerator position signal input (percentage of full travel) to the engine or machine controller.

APPROVED
Fuel System & Air Induction
SPN:91

SPN 94 — Engine Fuel Delivery Pressure

Low-pressure fuel transfer/lift pump supply pressure measured upstream of the high-pressure common-rail injection pump.

APPROVED
Fuel System & Air Induction
SPN:94

SPN 97 — Water in Fuel Indicator 1

Conductivity/capacitance probe in the primary fuel-water separator bowl detecting accumulated water in diesel fuel.

APPROVED
Fuel System & Air Induction
SPN:97

SPN 100 — Engine Oil Pressure

Main rifle engine lubricating oil gallery pressure monitored for engine protection and low-oil-pressure shutdown.

APPROVED
Engine Cooling & Lubrication
SPN:100

SPN 102 — Engine Intake Manifold #1 Pressure (Boost Pressure)

Positive gauge pressure in the intake manifold downstream of the turbocharger and charge-air cooler.

APPROVED
Fuel System & Air Induction
SPN:102

SPN 105 — Engine Intake Manifold #1 Temperature

Charge-air temperature entering the engine intake manifold after the aftercooler/intercooler.

APPROVED
Fuel System & Air Induction
SPN:105

SPN 110 — Engine Coolant Temperature

Engine block/thermostat housing coolant temperature used for thermal protection, fan control, and cold-start fueling.

APPROVED
Engine Cooling & Lubrication
SPN:110

SPN 111 — Engine Coolant Level 1

Surge tank / radiator top-tank coolant level switch or probe monitoring for coolant loss.

APPROVED
Engine Cooling & Lubrication
SPN:111

SPN 157 — Engine Injector Metering Rail 1 Pressure

High-pressure common-rail (HPCR) fuel accumulator pressure measured for closed-loop injection control.

APPROVED
Fuel System & Air Induction
SPN:157

SPN 168 — Electrical Potential / Battery Potential (Power Input 1)

Main unswitched battery supply voltage (+12V or +24V nominal) measured at the ECM power input pins.

APPROVED
ECU Power & Sensor Supply
SPN:168
Showing 1 to 10 of 29 records

Source: Curated SAE J1939 Standard Parameter Reference (Reviewed 2026-11-02). Proprietary OEM range: SPN 520,192–524,287.

SAE J1939 Pinouts vs. Metered AI Diagnostic Sessions

Free Standards-Grounded J1939 Decoding + BYOD Manual Search vs. Metered AI Sessions

Why spend $12.95 to $99/month on AI Diesel Tech for 3 to 60 metered fault-tree sessions? Pair Rigovely’s 100% free SAE J1939 SPN/FMI decoder with flat-rate $49/mo Beta manual search to inspect factory wiring and troubleshooting procedures with zero session caps.

SAE J1939 Architecture & Scope Boundaries

How SAE J1939 SPN and FMI Bit-Packing Works

Every SAE J1939-73 Diagnostic Trouble Code (DTC) packs a 19-bit Suspect Parameter Number (SPN 1–524,287) with a 5-bit Failure Mode Identifier (FMI 0–31) inside a 4-byte Diagnostic Message (DM1 active / DM2 previously active).

Deterministic Triage

Worked Example: SPN 110 FMI 0 vs. SPN 110 FMI 3

Both fault codes point to SPN 110 (Engine Coolant Temperature), but the 5-bit FMI completely changes the technician’s first diagnostic action:

1. SPN 110 · FMI 0 (Data Valid Above Normal — Most Severe): Sensor signal is within valid electrical bounds; engine coolant is physically overheating. Inspect coolant level, radiator core restriction, water pump, and fan drive.

2. SPN 110 · FMI 3 (Voltage Above Normal / Shorted to High): Input voltage at the ECM exceeds the analog ceiling (~4.95V). On a 2-wire NTC thermistor with an internal ECM 5V pull-up resistor, an unplugged connector or broken wire causes FMI 3.

1. 2-Wire Passive vs. 3-Wire Active 5V vs. 4-Wire Smart CAN Sensors

Generic online fault code lists often instruct mechanics to “check for 5V or 12V/24V at the sensor plug” regardless of parameter. On modern heavy equipment, applying external test voltage or probing the wrong terminal can destroy an ECM driver:

  • 2-Wire NTC Thermistor (e.g. Coolant / Oil Temp): Uses internal ECM 5V pull-up; open circuit reads ~5.0V (sets FMI 3), shorted wire reads ~0.0V (sets FMI 4).
  • 3-Wire Active Hall / Piezo Pressure Sensor (e.g. Rail / Boost Pressure): Uses 5V reference, return ground, and 0.5V–4.5V signal; broken signal wire typically pulls low (<0.2V, setting FMI 4).
  • 4-Wire CAN Smart Sensor (e.g. SPN 3216 / 3226 NOx Module): Connects to battery +12V/+24V, ground, and J1939 CAN High/Low; communicates digitally (often logs FMI 2, 9, 12, or 19).

2. Standard SPNs vs. Proprietary Manufacturer Range (520,192–524,287)

Under SAE J1939-73 (Bendix SD-13-48699 Reference) and TE Connectivity DEUTSCH HD10-9-1939, the 19-bit SPN space reserves integers 520,192 through 524,287 for OEM-proprietary assignment.

When a machine monitor displays a proprietary SPN (or an OEM-specific event code), the 5-bit FMI (0–31) still follows the standard electrical/operational classification, but the component identity must be verified in the OEM service manual for that exact model and serial number prefix.

Mechanical and Hydraulic Checks After the Sensor

When an active code logs FMI 0, FMI 1, FMI 7, or FMI 15–18 on a pressure or fluid-level parameter, the electrical sensor loop is reporting a real hydraulic or mechanical anomaly.

If your inspection uncovers a weeping pressure transducer port, damaged O-ring face seal, or loose manifold bracket, use our Hydraulic Fitting Torque & Thread Reference for JIC 37°, ORFS, and SAE O-Ring Boss port assembly specs, our AS568 Hydraulic O-Ring Size & Caliper Matcher to identify replacement boss seals, or our Fastener Preload & Bolt Torque Calculator for mounting hardware.

SHOP SOFTWARE GUIDE · VERIFIED 2026 PRICING

Comparing Free J1939 SPN/FMI Decoding vs. Metered AI Diagnostic Sessions?

See how Rigovely’s free SAE J1939 decoder + flat $49/mo BYOD manual search compares against AI Diesel Tech’s $12.95–$199/mo metered sessions and 6 alternatives.

SHOP SOFTWARE GUIDE · VERIFIED 2026 PRICING

Hitting 50-Credit Monthly Caps Looking Up J1939 Fault Trees & Schematics?

See how Rigovely’s unlimited BYOD manual retrieval + free J1939 decoder compares against Diesel Repair ($9.99–$249.99/mo), Noregon NextStep, and Cojali Jaltest OHW.

HEAVY EQUIPMENT DIAGNOSTIC GUIDE · 2026 PRICING

Using a Multi-Brand VCI Scanner on 9-Pin J1939 Off-Highway Ports?

Using a multi-brand VCI scanner on 9-pin J1939 off-highway ports? Compare Rigovely vs. Cojali Jaltest OHW or review the 6 Best Jaltest OHW Alternatives for 2026.

SHOP SOFTWARE GUIDE · VERIFIED 2026 PRICING

Decoded a fault code and need the exact wiring pinout across a mixed fleet?

Compare Rigovely vs. Cat SIS 2.0 & SIS2GO and review the 6 Best Cat SIS 2.0 Alternatives for 2026.

SHOP SOFTWARE GUIDE · VERIFIED 2026 PRICING

Decoded a monitor abnormality code and need physical ECM bi-directional testing?

Compare the 6 Best TroubleshootHD Alternatives in 2026 across physical VCI scanners (Jaltest OHW, JPRO) and cloud wiring databases.
Shop bench

Free shop calculators grounded in published standards (Parker Catalog 4300, SAE J1939, AS568). They run in the browser with no login and no paywall.

Need the Exact Factory Schematic or Torque Table for This Machine?

Stop scrolling through 1,200 to 4,000-page OEM PDFs on a phone screen. Upload your shop's Service and Test & Adjust manuals into Rigovely's isolated Scoped OEM Index. The Beta diagnostic co-pilot pinpoints the wiring pinout, relief pressure, or torque sequence by S/N prefix alongside Fleetio, SAP, or Maximo.

100% Shop-Controlled Library: Your internal manuals are encrypted and never used to train public AI models.Start 7-Day Free Trial - Upload Your Shop PDFs
View All Free Tools
Shop Downtime & ROI Scenario Calculator
01 · Fleet & Shop Economics

Shop Downtime & ROI Scenario Calculator

Model technician manual search friction, wrong-part restocking penalties, and independent equipment downtime using your shop’s actual repair order volume.

  • SMRP Metric 5.6.1
  • USACE EP 1110-1-8
  • Multi-Currency ROI
AS568 Hydraulic O-Ring Size & Nominal Gland Calculator
02 · SAE AS568 · Parker 2-xxx

AS568 Hydraulic O-Ring Size & Nominal Gland Calculator

Identify standard AS568 dash numbers and Parker 2-xxx designations from caliper ID and CS measurements with tolerance overlap and rectangular gland fill math.

  • SAE AS568 Rev D
  • Parker ORD 5700
  • 2D Interval Overlap
Hydraulic Fitting Torque & Thread Reference
03 · JIC 37° · ORFS · SAE ORB

Hydraulic Fitting Torque & Thread Reference

Look up thread designations, sealing mechanisms, and manufacturer assembly conditions for JIC 37° flare, ORFS face seal, and SAE O-ring boss connections.

  • SAE J514 · J1453
  • SAE J1926-1 ORB
  • No 0.75× Multipliers
Fastener Preload & Bolt Torque Calculator (T = K × F × d)
04 · ISO 898-1 · SAE J429

Fastener Preload & Bolt Torque Calculator (T = K × F × d)

Calculate tensile stress area (As), proof load, target clamp preload (F), and tightening torque (T = K × F × d) with explicit nut factor K and anti-seize yield risk simulation.

  • ISO 898-1 Class 8.8/10.9/12.9
  • SAE J429 Grade 5/8
  • Bossard F-047
SAE J518 4-Bolt Split Flange (Code 61 / Code 62 / CAT) Calculator
06 · SAE J518 · Parker 4300 T6

SAE J518 4-Bolt Split Flange (Code 61 / Code 62 / CAT) Calculator

Match caliper flange head OD, thickness, and bolt pattern to SAE Code 61, Code 62, or Caterpillar 14.22 mm (0.560") high-pressure flanges with AS568 O-ring and 3-step cross-bolt torque specs.

  • SAE J518 / ISO 6162
  • Code 62 vs CAT 14.22 mm
  • Parker Table T6
Hydraulic Cylinder Push/Pull Force, Cycle Time & Intensification Calculator
07 · ISO 3320 · Fluid Power

Hydraulic Cylinder Push/Pull Force, Cycle Time & Intensification Calculator

Calculate double-acting cylinder push and pull force, cycle time, oil volume, and rod-end pressure spike when the return port is blocked.

  • ISO 3320 Bore/Rod
  • Rod-End Pressure Spike
  • Single / Twin Cylinders