Hydraulic pump effective flow rate equals geometric displacement multiplied by shaft speed and volumetric efficiency (Q_L/min = (V_g × RPM × η_vol) / 1000 or GPM = (CIR × RPM × η_vol) / 231), required diesel engine input power equals P_kW = (Q_eff × Δp_bar) / (600 × η_total), and hydraulic motor output shaft torque equals T_N·m = (V_g × Δp_bar × η_mech) / (20π); a 100 cm³/rev (6.10 CIR) excavator axial piston pump at 2,000 RPM and 350 bar (5,076 psi) with 92% volumetric and 90% mechanical efficiency delivers 184.00 L/min (48.61 US GPM) effective flow (16.00 L/min case drain bypass) and requires 129.63 kW (173.84 HP) of engine input power.
Interactive Hydraulic Pump Flow, Engine Power, and Motor Torque Calculator
1. Hydraulic Pump or Motor Parameters
Select Pump Mode (flow rate, case drain loss & engine power) or Motor Mode (output shaft torque, RPM & mechanical power).
η_vol = (Q_loaded / Q_no_load) × 100. When an axial piston pump drops below 82% volumetric efficiency (or below 75% on an external gear pump), excessive internal oil bypasses into the case drain line, overheating the reservoir and slowing boom/travel speed.Hydraulic Pump Flow, Engine Power & Motor Torque Calculation Output
100.0 cm³/rev (6.10 CIR)
Δp = 350 bar (5,076 psi) · η_total = 82.8% (η_vol 92% × η_mech 90%)
Estimated internal rotary-group bypass to case drain is 16.00 L/min (4.23 US GPM) at 350 bar (5,076 psi). Internal slip is within normal operating limits for ISO VG 46 hydraulic oil at working temperature.
Every positive-displacement pump or motor experiences internal clearance slip across the valve plate, piston slippers, or gear teeth (Q_loss = Q_theo − Q_eff). Because the prime mover must supply both volumetric slip losses (η_vol) and mechanical friction losses (η_mech), required engine power divides fluid power by η_overall = η_vol × η_mech.
Calculations follow ISO/DIN and SAE fluid power equations for positive-displacement pumps and motors (Q = V_g × n × η_vol / 1000, P_kW = Q_eff × Δp / (600 × η_total), and T_N·m = V_g × Δp / (20π)). Variable-displacement excavator pumps equipped with constant-horsepower regulators reduce displacement V_g automatically once circuit pressure exceeds the torque-limiter cut-in setting.
Sources: Bosch Rexroth Axial Piston Units Engineering Reference (RE 90220) & Parker Hannifin Pump & Motor Division Engineering Reference (Catalog HY13-PM). Reviewed 2026-11-02 by Rigovely Lead Hydraulic Systems Engineer.
Need Exact OEM Case Drain Limits, PC/LS Regulator Curves & Test Port Locations?
Condemning a $12,000 excavator main pump or final drive travel motor requires the exact allowable case drain L/min table, power-shift EPC current curve, and regulator adjustment procedure for your machine’s serial number prefix. Rigovely searches the manuals your shop already owns and returns the cited page in seconds.
100% browser-local calculation. Your flow-meter readings and displacement measurements are never sent to analytics.
No-Load Flow Is Not Rated Flow Under Load: Case Drain Bypass & Engine Stall Guardrails
This utility computes steady-state positive-displacement pump flow, internal case drain bypass loss, required diesel engine input power, and hydraulic motor shaft torque. In variable-displacement load-sensing or horsepower-regulated pumps, actual displacement (V_g) automatically destrokes above the regulator knee pressure. Always verify test port pressures and case drain limits against your OEM service manual:
No-Load Flow vs. Flow Under Rated Pressure (η_vol)
An excavator pump with a scored valve plate or worn piston slippers can deliver normal L/min at 0 bar no-load, yet bypass >20% of its flow to the case drain line once loaded to 300–350 bar.
Diesel Engine Stall from Stuck Torque / HP Limiter
Variable-displacement excavator pumps rely on a horsepower/torque regulator (PC/LS valve) to destroke V_g as pressure climbs. If the regulator sticks at maximum swashplate angle, P_input = (Q × Δp) / (600 × η_t) exceeds engine torque and stalls the diesel engine.
Case Drain Back-Pressure Destroys Shaft Seals
When measuring case drain bypass flow into a graduated bucket or flow meter, never restrict the case drain hose. Housing pressure above 2–5 bar (30–75 psi) will blow out the pump or motor shaft lip seal.
Never Dead-Head a Flow Meter Without an Internal Relief
When load-testing a positive-displacement pump with a portable turbine flow meter and loading valve, always verify an upstream relief valve is active before closing the load restrictor.
Heavy Equipment Hydraulic Pump & Motor Displacement, Flow & Power Matrix
A 100 cm³/rev (6.10 CIR) excavator axial piston main pump section driven at 2,000 RPM and 350 bar delivers 184.0 L/min (48.6 US GPM) effective flow at 92% volumetric efficiency (16.0 L/min case drain slip) and demands 129.6 kW (173.8 HP) of diesel engine input power.
16 cm³/rev (0.98 CIR) Gear Pilot Pump
External Gear · HYDRAULIC PUMP
36 cm³/rev (2.20 CIR) External Gear Pump
External Gear · HYDRAULIC PUMP
45 cm³/rev (2.75 CIR) Cartridge Vane Pump
Industrial Vane · HYDRAULIC PUMP
71 cm³/rev (4.33 CIR) Axial Piston Pump
Axial Piston · HYDRAULIC PUMP
100 cm³/rev (6.10 CIR) Axial Piston Main Pump
Axial Piston · HYDRAULIC PUMP
140 cm³/rev (8.54 CIR) Axial Piston Main Pump
Axial Piston · HYDRAULIC PUMP
200 cm³/rev (12.20 CIR) Tandem Axial Piston Pump
Axial Piston · HYDRAULIC PUMP
280 cm³/rev (17.09 CIR) Mining Axial Piston Pump
Axial Piston · HYDRAULIC PUMP
28 cm³/rev (1.71 CIR) Hydraulic Fan Drive Motor
External Gear · HYDRAULIC MOTOR
80 cm³/rev (4.88 CIR) Excavator Swing Motor
Axial Piston · HYDRAULIC MOTOR
Source: Bosch Rexroth Axial Piston Reference RE 90220 & Parker Hannifin Catalog HY13-PM (Reviewed 2026-11-02).
Pump and Motor Case Drain Wear Checks
Distinguish between internal rotary-group case drain wear (high case drain flow, no engine lugging), stuck horsepower/torque regulators (severe diesel engine lugging/stall), and swing/travel motor crossover relief leaks.
No-Load Flow Is Normal, But Flow Collapses Above 250–350 bar as Oil Warms Up
Excessive Internal Bypass (η_vol < 82% Piston / < 75% Gear)
Diesel Engine Lugs Heavily, Blows Black/Blue Smoke, or Stalls Dead Under Load
Horsepower / Torque Limiter Regulator Failure
High-Pitched Marbles/Rattling Noise at Pump Housing & Spongy Jerky Actuators
Pump Suction Cavitation vs. Shaft Seal Aeration
Travel or Swing Motor Lacks Torque in One or Both Directions & Overheats Rapidly
Swing / Travel Motor Crossover Relief or Parking Brake Drag
Hydraulic Pump Flow, Engine Power & Motor Torque Methodology
Positive-displacement pump output flow and required prime-mover engine power are governed by geometric displacement (V_g), shaft speed (n), pressure differential (Δp), and the separation of volumetric slip (η_vol) from mechanical friction (η_mech).
Worked Example: 100 cm³/rev Pump @ 2,000 RPM & 350 bar
Given an excavator axial piston pump with V_g = 100 cm³/rev (6.102 CIR), n = 2,000 RPM, Δp = 350 bar (5,076 psi), η_vol = 92%, and η_mech = 90%:
1. Theoretical Flow Q_theo = (100 × 2,000) / 1,000 = 200.00 L/min (52.83 US GPM)
2. Effective Flow Q_eff = 200.00 × 0.92 = 184.00 L/min (48.61 US GPM)
3. Case Drain Slip Q_loss = 200.00 − 184.00 = 16.00 L/min (4.23 US GPM)
4. Fluid Power P_hyd = (184.00 × 350) / 600 = 107.33 kW (143.94 HP)
5. Overall Efficiency η_total = 0.92 × 0.90 = 0.828 (82.8%)
6. Required Engine Power P_input = 107.333 / 0.828 = 129.63 kW (173.84 HP)
7. Pump Input Shaft Torque T_pump = (100 × 350) / (20π × 0.90) = 618.94 N·m (456.50 lbf·ft)
1. Mode 1 — Hydraulic Pump Flow Rate, Case Drain Bypass & Engine Power
Per Bosch Rexroth Axial Piston Reference RE 90220 and Parker Hannifin Pump & Motor Engineering Reference, pump delivery decreases under load due to internal clearance leakage into the housing case drain:
- Q_theo (L/min) = [V_g (cm³/rev) × n (RPM)] / 1,000 | Q_theo (GPM) = [CIR × RPM] / 231
- Q_eff (L/min) = Q_theo × (η_vol / 100) | Q_loss (Case Drain) = Q_theo − Q_eff
- P_input (kW) = [Q_eff (L/min) × Δp (bar)] / [600 × (η_vol/100) × (η_mech/100)]
- P_input (HP) = [Q_eff (GPM) × Δp (psi)] / [1,714 × η_overall]
- T_pump (N·m) = [V_g (cm³/rev) × Δp (bar)] / [20π × (η_mech / 100)]
2. Mode 2 — Hydraulic Motor Output Torque, Shaft Speed & Mechanical Power
In a hydraulic swing, track travel, or winch motor, fluid flow entering the work port (Q_in) suffers volumetric slip before turning the output shaft, while mechanical friction reduces theoretical torque:
- T_eff (N·m) = [V_g (cm³/rev) × Δp (bar) × (η_mech / 100)] / (20π)
- T_eff (lbf·in) = [CIR × Δp (psi) × (η_mech / 100)] / (2π) | T_eff (lbf·ft) = T_lbf·in / 12
- n_eff (RPM) = [(Q_in (L/min) × 1,000) / V_g (cm³/rev)] × (η_vol / 100)
- P_shaft (kW) = [T_eff (N·m) × n_eff (RPM)] / 9,549.2966
3. Canonical SI Conversion Constants & Volumetric Wear Thresholds
All unit toggles project from canonical double-precision SI values without round-trip drift:
- 1 in³/rev (CIR) = 16.387064 cm³/rev | 1 US Gal = 231 in³ = 3.785411784 L
- 1 bar = 14.503773773 psi | 1 mechanical HP = 0.745699872 kW
- 1 lbf·ft = 1.355817948 N·m = 12 lbf·in
- Critical Bypass Warning: η_vol < 82% (Axial Piston), < 80% (Vane), < 75% (External Gear)
4. Complete Heavy Equipment Hydraulic Bench & Bay Workflow
Once effective pump flow rate (Q_eff) and working pressure (Δp) are verified, size suction inlet lines (2–4 ft/s), return lines (5–10 ft/s), and high-pressure working hoses (10–20 ft/s) in the Hydraulic Hose Dash Size, Flow Velocity & SAE 100R Working Pressure Calculator, and feed that flow into the Hydraulic Cylinder Push/Pull Force, Cycle Time & Intensification Calculator to verify boom and stick cylinder extend/retract speeds. When disconnecting pump discharge lines or travel motor ports, identify 4-bolt split flanges (Code 61 vs. Code 62 vs. CAT 14.22 mm) in the SAE J518 4-Bolt Split Flange Size & Torque Calculator, match case drain and flange face seals in the AS568 Hydraulic O-Ring Size & Gland Calculator, and check JIC 37° / ORFS assembly torque in the Hydraulic Fitting Torque & Thread Reference.
For British BSPP, Japanese JIS 30°, Komatsu metric, or DIN 2353 pump adapters, use the International Hydraulic Thread & Seat Angle Caliper Identifier, compute pump mounting flange fastener preload in the Fastener Preload & Bolt Torque Calculator (T = K × F × d), decode electronic pump regulator CAN fault codes in the SAE J1939 Fault Code (SPN/FMI) & Deutsch 9-Pin Reference, and evaluate shop downtime savings in the Shop Downtime & ROI Scenario Calculator.
Diagnosing Off-Highway Hydraulic Pumps Across Mixed Yellow Iron?
Diagnosing off-highway hydraulic pumps across mixed yellow iron? Explore our Cojali Jaltest OHW vs. Rigovely Shop Review and Top 6 Jaltest OHW Alternatives.
Pump strainer clogging or unload valve relief pressure out of spec?
Related Free Heavy Equipment Shop Tools
Free shop calculators grounded in published standards (Parker Catalog 4300, SAE J1939, AS568). They run in the browser with no login and no paywall.
Need the Exact Factory Schematic or Torque Table for This Machine?
Stop scrolling through 1,200 to 4,000-page OEM PDFs on a phone screen. Upload your shop's Service and Test & Adjust manuals into Rigovely's isolated Scoped OEM Index. The Beta diagnostic co-pilot pinpoints the wiring pinout, relief pressure, or torque sequence by S/N prefix alongside Fleetio, SAP, or Maximo.
100% Shop-Controlled Library: Your internal manuals are encrypted and never used to train public AI models.Start 7-Day Free Trial - Upload Your Shop PDFs
Shop Downtime & ROI Scenario Calculator
Model technician manual search friction, wrong-part restocking penalties, and independent equipment downtime using your shop’s actual repair order volume.
- SMRP Metric 5.6.1
- USACE EP 1110-1-8
- Multi-Currency ROI

AS568 Hydraulic O-Ring Size & Nominal Gland Calculator
Identify standard AS568 dash numbers and Parker 2-xxx designations from caliper ID and CS measurements with tolerance overlap and rectangular gland fill math.
- SAE AS568 Rev D
- Parker ORD 5700
- 2D Interval Overlap

Hydraulic Fitting Torque & Thread Reference
Look up thread designations, sealing mechanisms, and manufacturer assembly conditions for JIC 37° flare, ORFS face seal, and SAE O-ring boss connections.
- SAE J514 · J1453
- SAE J1926-1 ORB
- No 0.75× Multipliers

Fastener Preload & Bolt Torque Calculator (T = K × F × d)
Calculate tensile stress area (As), proof load, target clamp preload (F), and tightening torque (T = K × F × d) with explicit nut factor K and anti-seize yield risk simulation.
- ISO 898-1 Class 8.8/10.9/12.9
- SAE J429 Grade 5/8
- Bossard F-047

SAE J1939 Fault Code (SPN/FMI) & Deutsch 9-Pin Reference
Decode 5-bit Failure Mode Identifiers (FMI 0–31), curated Suspect Parameter Numbers (SPN), proprietary OEM SPN ranges, and Deutsch HD10-9-1939 9-pin connector cavities.
- SAE J1939-73 FMI 0–31
- Deutsch HD10-9-1939
- Gateway Guardrails

SAE J518 4-Bolt Split Flange (Code 61 / Code 62 / CAT) Calculator
Match caliper flange head OD, thickness, and bolt pattern to SAE Code 61, Code 62, or Caterpillar 14.22 mm (0.560") high-pressure flanges with AS568 O-ring and 3-step cross-bolt torque specs.
- SAE J518 / ISO 6162
- Code 62 vs CAT 14.22 mm
- Parker Table T6