BOSCH REXROTH RE

Last Updated: November 2, 2026

Hydraulic Pump & Motor Displacement, Flow Rate (GPM / L/min), Horsepower & Torque Calculator

Hydraulic pump effective flow rate equals geometric displacement multiplied by shaft speed and volumetric efficiency (Q_L/min = (V_g × RPM × η_vol) / 1000 or GPM = (CIR × RPM × η_vol) / 231), required diesel engine input power equals P_kW = (Q_eff × Δp_bar) / (600 × η_total), and hydraulic motor output shaft torque equals T_N·m = (V_g × Δp_bar × η_mech) / (20π); a 100 cm³/rev (6.10 CIR) excavator axial piston pump at 2,000 RPM and 350 bar (5,076 psi) with 92% volumetric and 90% mechanical efficiency delivers 184.00 L/min (48.61 US GPM) effective flow (16.00 L/min case drain bypass) and requires 129.63 kW (173.84 HP) of engine input power.

Direct Specification Summary · Bosch Rexroth RE 90220 & ISO 4409Hydraulic pump output flow is Q = (Vg × RPM × η_vol) / 1000 in L/min, while internal case drain leakage equals Q_theo × (1 − η_vol). When axial piston pump case drain exceeds 8%–10% of theoretical flow under load, internal rotating-group wear is converting engine power directly into reservoir heat.

Interactive Hydraulic Pump Flow, Engine Power, and Motor Torque Calculator

Calculated hydraulic pump (100.0 cm³/rev (6.10 CIR)): Effective flow 184.00 L/min, case drain bypass 16.00 L/min (4.23 US GPM), required engine power 129.63 kW.

1. Hydraulic Pump or Motor Parameters

Select Pump Mode (flow rate, case drain loss & engine power) or Motor Mode (output shaft torque, RPM & mechanical power).

Operating Mode (Pump Flow & Engine Power vs. Motor Torque & Speed)
Quick Heavy Equipment Pump & Motor Benchmarks (Rexroth / Parker):
Rotary Group Design Family (Case Drain Wear Threshold)
In flow-meter load testing, η_vol = (Q_loaded / Q_no_load) × 100. When an axial piston pump drops below 82% volumetric efficiency (or below 75% on an external gear pump), excessive internal oil bypasses into the case drain line, overheating the reservoir and slowing boom/travel speed.

Hydraulic Pump Flow, Engine Power & Motor Torque Calculation Output

Deterministic Fluid Power Physics · Mode 1 · Hydraulic Pump Flow & Power

100.0 cm³/rev (6.10 CIR)

Δp = 350 bar (5,076 psi) · η_total = 82.8% (η_vol 92% × η_mech 90%)

Effective Pump Flow Rate Q_eff (@ 2000 RPM)
184.00 L/min
48.61 US GPM (Theoretical: 200.00 L/min)
Required Diesel Engine Input Power (P_input)
129.63 kW
173.84 HP (Fluid Power: 107.33 kW)
Volumetric Efficiency & Case Drain Bypass Diagnostic (η_vol = 92%)
HEALTHY VOLUMETRIC EFFICIENCY

Estimated internal rotary-group bypass to case drain is 16.00 L/min (4.23 US GPM) at 350 bar (5,076 psi). Internal slip is within normal operating limits for ISO VG 46 hydraulic oil at working temperature.

Case Drain Bypass (Q_loss)
16.00 L/min (4.23 US GPM)Theo Flow: 200.00 L/min (52.83 US GPM)
Fluid Hydraulic Power (P_hyd)
107.33 kW (143.94 HP)η_total: 82.8%
Pump Input Shaft Torque
618.94 N·mTheo: 557.04 N·m (410.85 lbf·ft)
Volumetric Flow Balance & Shaft Power Conversion SchematicQ_eff = Q_theo − Q_case_drain
Diesel Engine / ShaftP_in = Q×Δp/(600·η_t)n (RPM) · T_shaftRotary GroupV_g (cm³/rev)Effective Work Port FlowQ_eff = Q_theo × η_volP_hyd = Q_eff × Δp / 600Case Drain Bypass (Q_loss)Q_loss = Q_theo × (1 − η_vol)

Every positive-displacement pump or motor experiences internal clearance slip across the valve plate, piston slippers, or gear teeth (Q_loss = Q_theo − Q_eff). Because the prime mover must supply both volumetric slip losses (η_vol) and mechanical friction losses (η_mech), required engine power divides fluid power by η_overall = η_vol × η_mech.

Engineering Assumptions & Primary Source Provenance

Calculations follow ISO/DIN and SAE fluid power equations for positive-displacement pumps and motors (Q = V_g × n × η_vol / 1000, P_kW = Q_eff × Δp / (600 × η_total), and T_N·m = V_g × Δp / (20π)). Variable-displacement excavator pumps equipped with constant-horsepower regulators reduce displacement V_g automatically once circuit pressure exceeds the torque-limiter cut-in setting.

Sources: Bosch Rexroth Axial Piston Units Engineering Reference (RE 90220) & Parker Hannifin Pump & Motor Division Engineering Reference (Catalog HY13-PM). Reviewed 2026-11-02 by Rigovely Lead Hydraulic Systems Engineer.

Scoped OEM Manual Assistant

Need Exact OEM Case Drain Limits, PC/LS Regulator Curves & Test Port Locations?

Condemning a $12,000 excavator main pump or final drive travel motor requires the exact allowable case drain L/min table, power-shift EPC current curve, and regulator adjustment procedure for your machine’s serial number prefix. Rigovely searches the manuals your shop already owns and returns the cited page in seconds.

100% browser-local calculation. Your flow-meter readings and displacement measurements are never sent to analytics.

Volumetric Bypass, Torque Limiter & Flow-Bench Guardrail

No-Load Flow Is Not Rated Flow Under Load: Case Drain Bypass & Engine Stall Guardrails

This utility computes steady-state positive-displacement pump flow, internal case drain bypass loss, required diesel engine input power, and hydraulic motor shaft torque. In variable-displacement load-sensing or horsepower-regulated pumps, actual displacement (V_g) automatically destrokes above the regulator knee pressure. Always verify test port pressures and case drain limits against your OEM service manual:

No-Load Flow vs. Flow Under Rated Pressure (η_vol)

An excavator pump with a scored valve plate or worn piston slippers can deliver normal L/min at 0 bar no-load, yet bypass >20% of its flow to the case drain line once loaded to 300–350 bar.

Diesel Engine Stall from Stuck Torque / HP Limiter

Variable-displacement excavator pumps rely on a horsepower/torque regulator (PC/LS valve) to destroke V_g as pressure climbs. If the regulator sticks at maximum swashplate angle, P_input = (Q × Δp) / (600 × η_t) exceeds engine torque and stalls the diesel engine.

Case Drain Back-Pressure Destroys Shaft Seals

When measuring case drain bypass flow into a graduated bucket or flow meter, never restrict the case drain hose. Housing pressure above 2–5 bar (30–75 psi) will blow out the pump or motor shaft lip seal.

Never Dead-Head a Flow Meter Without an Internal Relief

When load-testing a positive-displacement pump with a portable turbine flow meter and loading valve, always verify an upstream relief valve is active before closing the load restrictor.

Bosch Rexroth RE

Heavy Equipment Hydraulic Pump & Motor Displacement, Flow & Power Matrix

A 100 cm³/rev (6.10 CIR) excavator axial piston main pump section driven at 2,000 RPM and 350 bar delivers 184.0 L/min (48.6 US GPM) effective flow at 92% volumetric efficiency (16.0 L/min case drain slip) and demands 129.6 kW (173.8 HP) of diesel engine input power.

Hydraulic Unit Category:

16 cm³/rev (0.98 CIR) Gear Pilot Pump

External Gear · HYDRAULIC PUMP

APPROVED
Excavator Pilot Charge / Brake Release Gear Pump2,000 RPM @ 40 bar (580 psi) · η_v 88% · η_m 86%
Flow Q_eff:28.2 L/min (7.4 GPM)
Power:2.5 kW (3.3 HP)
Torque:9 N·m (6 lbf·ft)

36 cm³/rev (2.20 CIR) External Gear Pump

External Gear · HYDRAULIC PUMP

APPROVED
Backhoe Loader Steering / Auxiliary Cooler Fan Circuit2,200 RPM @ 210 bar (3,046 psi) · η_v 88% · η_m 86%
Flow Q_eff:69.7 L/min (18.4 GPM)
Power:32.2 kW (43.2 HP)
Torque:103 N·m (76 lbf·ft)

45 cm³/rev (2.75 CIR) Cartridge Vane Pump

Industrial Vane · HYDRAULIC PUMP

APPROVED
Wheel Loader Brake & Steering Priority Circuit2,000 RPM @ 210 bar (3,046 psi) · η_v 89% · η_m 88%
Flow Q_eff:80.1 L/min (21.2 GPM)
Power:35.8 kW (48.0 HP)
Torque:132 N·m (98 lbf·ft)

71 cm³/rev (4.33 CIR) Axial Piston Pump

Axial Piston · HYDRAULIC PUMP

APPROVED
13–15 Ton Excavator / Forestry Harvester Load-Sensing Pump2,100 RPM @ 320 bar (4,641 psi) · η_v 93% · η_m 90%
Flow Q_eff:138.7 L/min (36.6 GPM)
Power:88.4 kW (118.5 HP)
Torque:325 N·m (240 lbf·ft)

100 cm³/rev (6.10 CIR) Axial Piston Main Pump

Axial Piston · HYDRAULIC PUMP

APPROVED
20-Ton Excavator (PC200 / 320 Class) Single Main Pump Section2,000 RPM @ 350 bar (5,076 psi) · η_v 92% · η_m 90%
Flow Q_eff:184.0 L/min (48.6 GPM)
Power:129.6 kW (173.8 HP)
Torque:501 N·m (370 lbf·ft)

140 cm³/rev (8.54 CIR) Axial Piston Main Pump

Axial Piston · HYDRAULIC PUMP

APPROVED
30-Ton Excavator / Heavy Wheel Loader Implement Pump1,900 RPM @ 350 bar (5,076 psi) · η_v 93% · η_m 91%
Flow Q_eff:247.4 L/min (65.4 GPM)
Power:170.5 kW (228.7 HP)
Torque:710 N·m (523 lbf·ft)

200 cm³/rev (12.20 CIR) Tandem Axial Piston Pump

Axial Piston · HYDRAULIC PUMP

APPROVED
20-Ton Excavator Combined P1+P2 Total Displacement (2×100 cc)2,000 RPM @ 350 bar (5,076 psi) · η_v 92% · η_m 90%
Flow Q_eff:368.0 L/min (97.2 GPM)
Power:259.3 kW (347.7 HP)
Torque:1003 N·m (740 lbf·ft)

280 cm³/rev (17.09 CIR) Mining Axial Piston Pump

Axial Piston · HYDRAULIC PUMP

APPROVED
45–60 Ton Quarry Excavator High-Flow Main Pump1,800 RPM @ 350 bar (5,076 psi) · η_v 94% · η_m 92%
Flow Q_eff:473.8 L/min (125.2 GPM)
Power:319.6 kW (428.5 HP)
Torque:1435 N·m (1058 lbf·ft)

28 cm³/rev (1.71 CIR) Hydraulic Fan Drive Motor

External Gear · HYDRAULIC MOTOR

APPROVED
Radiator & Hydraulic Oil Cooler Reversing Fan Motor2,200 RPM @ 210 bar (3,046 psi) · η_v 89% · η_m 87%
Flow Q_eff:54.8 L/min (14.5 GPM)
Power:24.8 kW (33.2 HP)
Torque:81 N·m (60 lbf·ft)

80 cm³/rev (4.88 CIR) Excavator Swing Motor

Axial Piston · HYDRAULIC MOTOR

APPROVED
15–20 Ton Excavator Slew / Swing Drive Axial Piston Motor1,800 RPM @ 280 bar (4,061 psi) · η_v 92% · η_m 90%
Flow Q_eff:132.5 L/min (35.0 GPM)
Power:74.7 kW (100.1 HP)
Torque:321 N·m (237 lbf·ft)
Showing 1 to 10 of 12 records

Source: Bosch Rexroth Axial Piston Reference RE 90220 & Parker Hannifin Catalog HY13-PM (Reviewed 2026-11-02).

Flow-Meter & Case Drain Triage Matrix

Pump and Motor Case Drain Wear Checks

Distinguish between internal rotary-group case drain wear (high case drain flow, no engine lugging), stuck horsepower/torque regulators (severe diesel engine lugging/stall), and swing/travel motor crossover relief leaks.

Diagnostic Fault Mode:

No-Load Flow Is Normal, But Flow Collapses Above 250–350 bar as Oil Warms Up

Excessive Internal Bypass (η_vol < 82% Piston / < 75% Gear)

Scored brass valve plate, worn piston slippers/barrel bores, or blown gear pump thrust plates. Perform a timed graduated-bucket case drain test at stall pressure before condemning the main control valve.
Scope: All hydraulic functions supplied by the worn pump section (or single travel/swing motor)Flow / Case Drain: Flow meter reading at 300 bar drops >18%–25% below no-load flow; case drain line flow exceeds 10%–15% of rated output and case drain hose runs 15°C–25°C hotter than tank.
Engine & Pressure:Diesel engine RPM remains steady (no lugging) because pump hydraulic load is bypassing internally to case drain instead of building full work-port flow.

Diesel Engine Lugs Heavily, Blows Black/Blue Smoke, or Stalls Dead Under Load

Horsepower / Torque Limiter Regulator Failure

Stuck PC/horsepower torque-limiter spool, misadjusted power-shift proportional solenoid (EPC/PRV), or clogged pilot filter preventing servo piston destroke. Verify power-shift pilot pressure and fuel rail/boost health first.
Scope: Variable-displacement axial piston main pumps when boom/stick/travel are combinedFlow / Case Drain: Pump refuses to destroke swashplate angle as system pressure climbs above 200–350 bar, keeping displacement Vg locked near maximum.
Engine & Pressure:Required pump input power P_input = (Q × Δp) / (600 × η_t) exceeds diesel engine net flywheel power curve; engine RPM pulls down >300 RPM or stalls.

High-Pitched Marbles/Rattling Noise at Pump Housing & Spongy Jerky Actuators

Pump Suction Cavitation vs. Shaft Seal Aeration

Collapsed suction hose liner, plugged tank breather/suction strainer, cold high-viscosity oil (cavitation), or loose suction clamp / worn pump input shaft lip seal drawing air (aeration).
Scope: Entire hydraulic system; rapid brass/bronze glitter contamination in return filterFlow / Case Drain: Erratic pulsing flow meter reading at high engine RPM; foamy milky oil in sight glass (aeration) or localized vapor collapse (cavitation).
Engine & Pressure: violent gauge needle flutter (±30–60 bar spikes) and severe erosion pitting on valve plate kidney ports.

Travel or Swing Motor Lacks Torque in One or Both Directions & Overheats Rapidly

Swing / Travel Motor Crossover Relief or Parking Brake Drag

Compare motor case drain flow against crossover relief temperature, and tee a gauge into the brake release pilot port (typically 25–40 bar required to fully release multi-disc pack).
Scope: Isolated to left/right track final drive motor or upper-structure swing motorFlow / Case Drain: If motor case drain flow is normal (<5–8 L/min) at stall, rotary group is healthy—oil is bypassing across the crossover relief or counterbalance spool.
Engine & Pressure:Work port pressure stalls low in one direction (faulty crossover relief) or reaches full relief pressure while track barely turns (dragging spring-applied multi-disc brake).
Fluid Power Physics & Diagnostics

Hydraulic Pump Flow, Engine Power & Motor Torque Methodology

Positive-displacement pump output flow and required prime-mover engine power are governed by geometric displacement (V_g), shaft speed (n), pressure differential (Δp), and the separation of volumetric slip (η_vol) from mechanical friction (η_mech).

Shop check

Worked Example: 100 cm³/rev Pump @ 2,000 RPM & 350 bar

Given an excavator axial piston pump with V_g = 100 cm³/rev (6.102 CIR), n = 2,000 RPM, Δp = 350 bar (5,076 psi), η_vol = 92%, and η_mech = 90%:

1. Theoretical Flow Q_theo = (100 × 2,000) / 1,000 = 200.00 L/min (52.83 US GPM)

2. Effective Flow Q_eff = 200.00 × 0.92 = 184.00 L/min (48.61 US GPM)

3. Case Drain Slip Q_loss = 200.00 − 184.00 = 16.00 L/min (4.23 US GPM)

4. Fluid Power P_hyd = (184.00 × 350) / 600 = 107.33 kW (143.94 HP)

5. Overall Efficiency η_total = 0.92 × 0.90 = 0.828 (82.8%)

6. Required Engine Power P_input = 107.333 / 0.828 = 129.63 kW (173.84 HP)

7. Pump Input Shaft Torque T_pump = (100 × 350) / (20π × 0.90) = 618.94 N·m (456.50 lbf·ft)

1. Mode 1 — Hydraulic Pump Flow Rate, Case Drain Bypass & Engine Power

Per Bosch Rexroth Axial Piston Reference RE 90220 and Parker Hannifin Pump & Motor Engineering Reference, pump delivery decreases under load due to internal clearance leakage into the housing case drain:

  • Q_theo (L/min) = [V_g (cm³/rev) × n (RPM)] / 1,000 | Q_theo (GPM) = [CIR × RPM] / 231
  • Q_eff (L/min) = Q_theo × (η_vol / 100) | Q_loss (Case Drain) = Q_theo − Q_eff
  • P_input (kW) = [Q_eff (L/min) × Δp (bar)] / [600 × (η_vol/100) × (η_mech/100)]
  • P_input (HP) = [Q_eff (GPM) × Δp (psi)] / [1,714 × η_overall]
  • T_pump (N·m) = [V_g (cm³/rev) × Δp (bar)] / [20π × (η_mech / 100)]

2. Mode 2 — Hydraulic Motor Output Torque, Shaft Speed & Mechanical Power

In a hydraulic swing, track travel, or winch motor, fluid flow entering the work port (Q_in) suffers volumetric slip before turning the output shaft, while mechanical friction reduces theoretical torque:

  • T_eff (N·m) = [V_g (cm³/rev) × Δp (bar) × (η_mech / 100)] / (20π)
  • T_eff (lbf·in) = [CIR × Δp (psi) × (η_mech / 100)] / (2π) | T_eff (lbf·ft) = T_lbf·in / 12
  • n_eff (RPM) = [(Q_in (L/min) × 1,000) / V_g (cm³/rev)] × (η_vol / 100)
  • P_shaft (kW) = [T_eff (N·m) × n_eff (RPM)] / 9,549.2966

3. Canonical SI Conversion Constants & Volumetric Wear Thresholds

All unit toggles project from canonical double-precision SI values without round-trip drift:

  • 1 in³/rev (CIR) = 16.387064 cm³/rev | 1 US Gal = 231 in³ = 3.785411784 L
  • 1 bar = 14.503773773 psi | 1 mechanical HP = 0.745699872 kW
  • 1 lbf·ft = 1.355817948 N·m = 12 lbf·in
  • Critical Bypass Warning: η_vol < 82% (Axial Piston), < 80% (Vane), < 75% (External Gear)

4. Complete Heavy Equipment Hydraulic Bench & Bay Workflow

Once effective pump flow rate (Q_eff) and working pressure (Δp) are verified, size suction inlet lines (2–4 ft/s), return lines (5–10 ft/s), and high-pressure working hoses (10–20 ft/s) in the Hydraulic Hose Dash Size, Flow Velocity & SAE 100R Working Pressure Calculator, and feed that flow into the Hydraulic Cylinder Push/Pull Force, Cycle Time & Intensification Calculator to verify boom and stick cylinder extend/retract speeds. When disconnecting pump discharge lines or travel motor ports, identify 4-bolt split flanges (Code 61 vs. Code 62 vs. CAT 14.22 mm) in the SAE J518 4-Bolt Split Flange Size & Torque Calculator, match case drain and flange face seals in the AS568 Hydraulic O-Ring Size & Gland Calculator, and check JIC 37° / ORFS assembly torque in the Hydraulic Fitting Torque & Thread Reference.

For British BSPP, Japanese JIS 30°, Komatsu metric, or DIN 2353 pump adapters, use the International Hydraulic Thread & Seat Angle Caliper Identifier, compute pump mounting flange fastener preload in the Fastener Preload & Bolt Torque Calculator (T = K × F × d), decode electronic pump regulator CAN fault codes in the SAE J1939 Fault Code (SPN/FMI) & Deutsch 9-Pin Reference, and evaluate shop downtime savings in the Shop Downtime & ROI Scenario Calculator.

HEAVY EQUIPMENT DIAGNOSTIC GUIDE · 2026 PRICING

Diagnosing Off-Highway Hydraulic Pumps Across Mixed Yellow Iron?

Diagnosing off-highway hydraulic pumps across mixed yellow iron? Explore our Cojali Jaltest OHW vs. Rigovely Shop Review and Top 6 Jaltest OHW Alternatives.

SHOP SOFTWARE GUIDE · VERIFIED 2026 PRICING

Pump strainer clogging or unload valve relief pressure out of spec?

Looking beyond BYOD PDF tools for bi-directional active testing and multi-brand diagnostic coverage? Compare the 6 Best TroubleshootHD Alternatives for heavy equipment shops.
Shop bench

Free shop calculators grounded in published standards (Parker Catalog 4300, SAE J1939, AS568). They run in the browser with no login and no paywall.

Need the Exact Factory Schematic or Torque Table for This Machine?

Stop scrolling through 1,200 to 4,000-page OEM PDFs on a phone screen. Upload your shop's Service and Test & Adjust manuals into Rigovely's isolated Scoped OEM Index. The Beta diagnostic co-pilot pinpoints the wiring pinout, relief pressure, or torque sequence by S/N prefix alongside Fleetio, SAP, or Maximo.

100% Shop-Controlled Library: Your internal manuals are encrypted and never used to train public AI models.Start 7-Day Free Trial - Upload Your Shop PDFs
View All Free Tools
Shop Downtime & ROI Scenario Calculator
01 · Fleet & Shop Economics

Shop Downtime & ROI Scenario Calculator

Model technician manual search friction, wrong-part restocking penalties, and independent equipment downtime using your shop’s actual repair order volume.

  • SMRP Metric 5.6.1
  • USACE EP 1110-1-8
  • Multi-Currency ROI
AS568 Hydraulic O-Ring Size & Nominal Gland Calculator
02 · SAE AS568 · Parker 2-xxx

AS568 Hydraulic O-Ring Size & Nominal Gland Calculator

Identify standard AS568 dash numbers and Parker 2-xxx designations from caliper ID and CS measurements with tolerance overlap and rectangular gland fill math.

  • SAE AS568 Rev D
  • Parker ORD 5700
  • 2D Interval Overlap
Hydraulic Fitting Torque & Thread Reference
03 · JIC 37° · ORFS · SAE ORB

Hydraulic Fitting Torque & Thread Reference

Look up thread designations, sealing mechanisms, and manufacturer assembly conditions for JIC 37° flare, ORFS face seal, and SAE O-ring boss connections.

  • SAE J514 · J1453
  • SAE J1926-1 ORB
  • No 0.75× Multipliers
Fastener Preload & Bolt Torque Calculator (T = K × F × d)
04 · ISO 898-1 · SAE J429

Fastener Preload & Bolt Torque Calculator (T = K × F × d)

Calculate tensile stress area (As), proof load, target clamp preload (F), and tightening torque (T = K × F × d) with explicit nut factor K and anti-seize yield risk simulation.

  • ISO 898-1 Class 8.8/10.9/12.9
  • SAE J429 Grade 5/8
  • Bossard F-047
SAE J1939 Fault Code (SPN/FMI) & Deutsch 9-Pin Reference
05 · SAE J1939-73 · Deutsch 9-Pin

SAE J1939 Fault Code (SPN/FMI) & Deutsch 9-Pin Reference

Decode 5-bit Failure Mode Identifiers (FMI 0–31), curated Suspect Parameter Numbers (SPN), proprietary OEM SPN ranges, and Deutsch HD10-9-1939 9-pin connector cavities.

  • SAE J1939-73 FMI 0–31
  • Deutsch HD10-9-1939
  • Gateway Guardrails
SAE J518 4-Bolt Split Flange (Code 61 / Code 62 / CAT) Calculator
06 · SAE J518 · Parker 4300 T6

SAE J518 4-Bolt Split Flange (Code 61 / Code 62 / CAT) Calculator

Match caliper flange head OD, thickness, and bolt pattern to SAE Code 61, Code 62, or Caterpillar 14.22 mm (0.560") high-pressure flanges with AS568 O-ring and 3-step cross-bolt torque specs.

  • SAE J518 / ISO 6162
  • Code 62 vs CAT 14.22 mm
  • Parker Table T6