OPEN-SOURCE MIT

Last Updated: November 11, 2026

Open-Source SAE J1939 & CAN .DBC File Editor, 64-Bit Matrix Visualizer & Frame Decoder

In Vector DBC syntax (SAE J1939-71), physical signal values equal Physical = (Raw × Scale) + Offset, while 29-bit J1939 CAN identifiers set bit 31 (BO_ID = CAN_ID_29 | 0x80000000) to form the 32-bit decimal BO_ message header.

Interactive SAE J1939 & CAN .DBC 64-Bit Signal Matrix & Frame Decoder

Decoded Physical Value · SPN 190

1800.00 rpm

● Valid Signal (SAE J1939-71) · Raw = 14400 (0x3840)

32-Bit Vector DBC Header
BO_ 2364539904
29-Bit CAN ID: 0x0CF00400
64-Bit CAN Payload Matrix (8 Bytes × 8 Bits) — EngineSpeed_SPN190@1 Intel Little-Endian (Sequential LSB → MSB)
64-Bit SAE J1939 & Vector DBC Signal Bit MatrixVisual 8-byte by 8-bit grid highlighting occupied signal bits, LSB/MSB positions, companion signals, and bit-overlap collisions.Bit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1Bit 0B0 (0xF0)B1 (0x7D)B2 (0x82)B3 (0x40)B4 (0x38)B5 (0x00)B6 (0xFF)B7 (0xFF)b71b61b51b41b30b20b10b00b150b141b131b121b111b101b90b81b231b220b210b200b190b180b171b160b310b301b290b280b270b260b250b240LSBb390MSBb380b371b361b351b340b330b320b470b460b450b440b430b420b410b400b551b541b531b521b511b501b491b481b631b621b611b601b591b581b571b561
Primary Signal (EngineSpeed_SPN190)Companion Signals in BO_Bit-Overlap Collision
PGN Number
61444 (0xF004)
PF=0xF0 · PDU2 Broadcast
Bit Footprint
24|16
Bit 24 → Bit 39 (16 bits)
Scale & Offset
(0.125, 0)
Raw × Scale + Offset
Source Address
0x00 (SA 0)
Priority 3
Generated Vector .DBC Definition & SocketCAN Filter
BO_ 2364539904 EEC1: 8 Vector__XXX
 SG_ EngineSpeed_SPN190 : 24|16@1+ (0.125,0) [0|8031.875] "rpm" Vector__XXX
candump vcan0,0CF00400:1FFFFFFF
SAE J1939-71

Open-Standard Public SAE J1939 PGN / SPN to Vector .DBC Reference Table

Deterministic lookup table mapping public SAE J1939 Parameter Group Numbers (PGN) and Suspect Parameter Numbers (SPN) to their 29-bit CAN IDs, 32-bit Vector DBC BO_ decimal headers, start bits, scales, and offsets.

PGN 61444 · SPN 190

EEC1
Signal:EngineSpeed_SPN190
Bit Footprint:24|16@1+
32-Bit BO_ ID:BO_ 2364539904
Scale & Offset:(0.125, 0) rpm

PGN 61444 · SPN 513

EEC1
Signal:ActualEngineTorque_SPN513
Bit Footprint:16|8@1+
32-Bit BO_ ID:BO_ 2364539904
Scale & Offset:(1, -125) %

PGN 65253 · SPN 247

HOURS
Signal:EngineTotalHours_SPN247
Bit Footprint:0|32@1+
32-Bit BO_ ID:BO_ 2566841600
Scale & Offset:(0.05, 0) h

PGN 65262 · SPN 110

ET1
Signal:EngineCoolantTemp_SPN110
Bit Footprint:0|8@1+
32-Bit BO_ ID:BO_ 2566843904
Scale & Offset:(1, -40) degC

PGN 65262 · SPN 175

ET1
Signal:EngineOilTemp1_SPN175
Bit Footprint:16|16@1+
32-Bit BO_ ID:BO_ 2566843904
Scale & Offset:(0.03125, -273) degC

PGN 65263 · SPN 100

EFL_P1
Signal:EngineOilPressure_SPN100
Bit Footprint:24|8@1+
32-Bit BO_ ID:BO_ 2566844160
Scale & Offset:(4, 0) kPa

PGN 65266 · SPN 183

LFE1
Signal:EngineFuelRate_SPN183
Bit Footprint:0|16@1+
32-Bit BO_ ID:BO_ 2566844928
Scale & Offset:(0.05, 0) L/h

PGN 65271 · SPN 168

VEP1
Signal:BatteryPotential_SPN168
Bit Footprint:32|16@1+
32-Bit BO_ ID:BO_ 2566846208
Scale & Offset:(0.05, 0) V
PROTOCOL SPECIFICATION & BITWISE DERIVATIONS

Vector .DBC Grammar, 32-Bit BO_ Extended CAN IDs & 64-Bit Endianness Math

Whether you are configuring a Linux SocketCAN telematics gateway, parsing heavy-equipment CAN logs with Python cantools, or building a custom diagnostic display, every SAE J1939 parameter follows bitwise packing rules governed by SAE J1939-21, SAE J1939-71, and the Vector DBC file format.

1. 29-Bit SAE J1939 CAN ID to 32-Bit Vector DBC BO_ Header

An SAE J1939-21 Extended Frame Format (EFF) identifier packs Priority (3 bits), Data Page (2 bits), PDU Format PF (8 bits), PDU Specific PS (8 bits), and Source Address SA (8 bits) into 29 bits. To distinguish 29-bit extended frames from 11-bit standard CAN frames inside a .dbc file, Vector sets Bit 31 (0x80000000):

CAN_ID_29 = (Priority << 26) | (DP << 24) | (PF << 16) | (PS << 8) | SA
DBC_BO_ID_32 = (0x80000000 | CAN_ID_29) >>> 0
Example EEC1 (0x0CF00400): 217,056,256 + 2,147,483,648 = BO_ 2364539904

2. Intel Little-Endian (@1) vs. Motorola Big-Endian (@0) Matrix Indexing

In Vector DBC SG_ definitions, bit numbering spans 0 to 63 across an 8-byte frame (Byte 0 = bits 0..7, Byte 7 = bits 56..63):

@1 Intel: BitSequence = [startBit, startBit + 1, ..., startBit + L - 1]
@0 Motorola: b_(k+1) = (b_k % 8 > 0) ? (b_k - 1) : (b_k + 15)
Physical = (Raw_Integer × Scale) + Offset

Published Engineering References & Protocol Standards

FREQUENTLY ASKED QUESTIONS

SAE J1939 & Vector .DBC File Format Engineering FAQs

Technical answers on 32-bit BO_ message IDs, @1 Intel vs @0 Motorola byte ordering, 0xFE / 0xFF status indicators, and PDU1 vs PDU2 PGN extraction.

In the Vector DBC specification, extended 29-bit CAN identifiers must set Bit 31 (0x80000000 = 2,147,483,648 decimal) as an Extended Frame Format (EFF) flag. Therefore, CAN ID 0x18F00400 (418,382,848 decimal) is stored in a .dbc file as BO_ 2565866496 (0x80000000 | 0x18F00400 = 0x98F00400 = 2,565,866,496). Similarly, priority-3 EEC1 (0x0CF00400 = 217,056,256) becomes BO_ 2364539904 (0x8CF00400).

Heavy Equipment Telematics & Shop Diagnostics

Turn Live J1939 PGN & DM1 Streams into Automated Shop Work Orders

Decoding .dbc signals is step one — raising mechanic wrench time from the 35% industry baseline to the 55% world-class benchmark expands productive shop capacity by +57% (SMRP Metric 5.6.1). Rigovely connects J1939 fault and fluid telemetry directly to machine-specific service procedures and parts lists.

Shop bench

Free shop calculators grounded in published standards (Parker Catalog 4300, SAE J1939, AS568). They run in the browser with no login and no paywall.

Need the Exact Factory Schematic or Torque Table for This Machine?

Stop scrolling through 1,200 to 4,000-page OEM PDFs on a phone screen. Upload your shop's Service and Test & Adjust manuals into Rigovely's isolated Scoped OEM Index. The Beta diagnostic co-pilot pinpoints the wiring pinout, relief pressure, or torque sequence by S/N prefix alongside Fleetio, SAP, or Maximo.

100% Shop-Controlled Library: Your internal manuals are encrypted and never used to train public AI models.Start 7-Day Free Trial - Upload Your Shop PDFs
View All Free Tools
Shop Downtime & ROI Scenario Calculator
01 · Fleet & Shop Economics

Shop Downtime & ROI Scenario Calculator

Model technician manual search friction, wrong-part restocking penalties, and independent equipment downtime using your shop’s actual repair order volume.

  • SMRP Metric 5.6.1
  • USACE EP 1110-1-8
  • Multi-Currency ROI
AS568 Hydraulic O-Ring Size & Nominal Gland Calculator
02 · SAE AS568 · Parker 2-xxx

AS568 Hydraulic O-Ring Size & Nominal Gland Calculator

Identify standard AS568 dash numbers and Parker 2-xxx designations from caliper ID and CS measurements with tolerance overlap and rectangular gland fill math.

  • SAE AS568 Rev D
  • Parker ORD 5700
  • 2D Interval Overlap
Hydraulic Fitting Torque & Thread Reference
03 · JIC 37° · ORFS · SAE ORB

Hydraulic Fitting Torque & Thread Reference

Look up thread designations, sealing mechanisms, and manufacturer assembly conditions for JIC 37° flare, ORFS face seal, and SAE O-ring boss connections.

  • SAE J514 · J1453
  • SAE J1926-1 ORB
  • No 0.75× Multipliers
Fastener Preload & Bolt Torque Calculator (T = K × F × d)
04 · ISO 898-1 · SAE J429

Fastener Preload & Bolt Torque Calculator (T = K × F × d)

Calculate tensile stress area (As), proof load, target clamp preload (F), and tightening torque (T = K × F × d) with explicit nut factor K and anti-seize yield risk simulation.

  • ISO 898-1 Class 8.8/10.9/12.9
  • SAE J429 Grade 5/8
  • Bossard F-047
SAE J1939 Fault Code (SPN/FMI) & Deutsch 9-Pin Reference
05 · SAE J1939-73 · Deutsch 9-Pin

SAE J1939 Fault Code (SPN/FMI) & Deutsch 9-Pin Reference

Decode 5-bit Failure Mode Identifiers (FMI 0–31), curated Suspect Parameter Numbers (SPN), proprietary OEM SPN ranges, and Deutsch HD10-9-1939 9-pin connector cavities.

  • SAE J1939-73 FMI 0–31
  • Deutsch HD10-9-1939
  • Gateway Guardrails
SAE J518 4-Bolt Split Flange (Code 61 / Code 62 / CAT) Calculator
06 · SAE J518 · Parker 4300 T6

SAE J518 4-Bolt Split Flange (Code 61 / Code 62 / CAT) Calculator

Match caliper flange head OD, thickness, and bolt pattern to SAE Code 61, Code 62, or Caterpillar 14.22 mm (0.560") high-pressure flanges with AS568 O-ring and 3-step cross-bolt torque specs.

  • SAE J518 / ISO 6162
  • Code 62 vs CAT 14.22 mm
  • Parker Table T6